WAGNER ZIP52 Translation Of The Original Operating Manual page 31

Pneumatic double diaphragm pump
Table of Contents

Advertisement

Operating manual Pneumatic double diaphragm pump ZIP52 - ZIP80
6   Assembly and Commissioning
1
2
3
9
8
7
6
1
Product delivery valve
2
Product hose
3
Return valve
4
Delivery manifold
5
Suction manifold
1. Install the pump on a flat and horizontal foundation and screw it down tightly or mount
it on a wall mount.
2. Connect the suction system and air supply.
3. Connect the material and air supply in accordance with the superordinate operating
manual.
Product connection:
Connect the pump's suction hose to the suction manifold (on the underside). Connect it to
the product hose's delivery manifold (on the upper side). Use flexible hoses to absorb the
pump's vibrations. Ensure that the hoses are not mechanically stressing the pump. Never
directly connect the pump to rigid pipes. For pumps installed in areas subject to explosion
hazards, all hoses and pipes must be made of conductive material and must be grounded.
Install a suction filter on the suction hose. This prevents particles, that are large enough to
damage the internal parts of the pump, from entering the pump. Observe the information
contained in the Technical Data section regarding the maximum size of solids that can be
pumped.
All hoses, pipes and components connected to the supply line must be designed to operate
at the pump's maximum pressure with the pump working at a vigorous rate. All parts
connected to the suction manifold must withstand crushing despite the vacuum produced
by the pump.
The suction and product hoses and pipes must have a cross-section proportional to the flow
rate and the viscosity of the pumped fluid. Avoid long and bent pipes, especially during
suctioning.
Order number DOC 2330426 | Edition 09/2021
4
5
B_06951
6
7
8
9
Air suction filter
Suction hose
Air cut-off valve
Air pressure regulator
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zip80

Table of Contents