WAGNER ZIP52 Translation Of The Original Operating Manual page 36

Pneumatic double diaphragm pump
Table of Contents

Advertisement

Operating manual Pneumatic double diaphragm pump ZIP52 - ZIP80
6   Assembly and Commissioning
6.7.3   Pressure Tightness Test
WARNING
Overpressure!
Risk of injury from bursting components.
4 The operating pressure must not exceed the value shown on the type plate.
1. Gradually increase the pressure in pump with the pressure regulator until maximum
pressure is reached. Maintain the pressure for 3 minutes and check all connection
points for leaks.
2. Carry out pressure relief in accordance with Chapter Pressure Relief / Work Interruption
[8 38].
6.7.4   Verifying a Safe Operational Condition
A skilled person must check to ensure that the device is in a reliable state after it is
assembled and commissioned. This includes:
4 Carry out safety checks in accordance with Chapter Safety Checks and Maintenance
Intervals [8 42].
6.7.5   Filling with Working Product
4 Proceed in accordance with Chapter Filling the Empty Pump [8 45].
36
Order number DOC 2330426 | Edition 09/2021