Associated status bits
0x00100000
6.6.5
Sensor temperature out of limits
NE107 alert: Offspec; Plantweb
The sensor temperature is outside the transmitter's operating range.
Recommended actions
Default configuration
Enabled
LCD display message
TEMP^OUT LIMITS
Associated status bits
0x00008000
6.6.6
Display update failure
NE107 and Plantweb
The display is not receiving updates from the electronics board.
Recommended actions
Default configuration
Enabled
LCD display message
N/A
Associated status bits
0x00000010
Reference Manual
Check the process and ambient temperature conditions are within -85 to 194 °F
(-65 to 90 °C).
Replace the sensor module.
alert: Maintenance
Check the connection between the display and the electronics board.
Replace the display.
Replace the electronics board.
alert: Maintenance
Troubleshooting