OPERATION

This section provides precautions at test run and operation. For instructions on test run and opera-
tion, refer to Σ-II PLUS Series SGMVH/SGDP User's Manual Design and Maintenance (SIE-
S800-33.12).
5.1
Precautions at Test Run
D To avoid inadvertent accidents, run the SERVOMOTOR only in test run (without load).
Failure to observe this caution may result in personal injury.
D Before starting operation with a load connected, set up parameters suitable for the machine.
Starting operation without setting up parameters may lead to overrun failure.
D Before starting operation with a connected load, make sure emergency-stop procedures are in
place.
Failure to observe this caution may result in personal injury.
J Conducting Test Run with Servomotor Connected to Machine
SERVOPACK initial parameters setting is performed assuming normal operation conditions.
Before test run, set up parameters suitable for the machine.
Failure to set up the parameter initial setting may result in machine overrun or breakdown.
As for the setting procedures and methods, refer to Σ-II PLUS Series SGM
Manual Design and Maintenance (SIE-S800-33.12).
J Check Item during Test Run
The following items should be checked during test run.
D Unusual vibration
D Abnormal noise
D Excessive temperature rise
5.2

Precautions at Operation

D During operation, do not touch the SERVOPACK's heat sink.
Failure to observe this caution may result in burns.