Σ−II PLUS Series SGDP SERVOPACK is a base-mount type servo controller. Incorrect installation
will cause problems. Always observe the installation instructions described below.
D Never use the equipment where it may be exposed to splashes of water, corrosive or flammable
gases, or near flammable materials.
Failure to observe this caution may lead to electric shock or fire.
3.1
Storage
When the SERVOPACK is to be stored with the power cable disconnected, store it in the fol-
lowing temperature range:
Between −20 µ +85 C_
3.2

Installation Sites

For installation sites, use proper care with the following notes.
When installed in a control panel
When installed near a heating unit
When installed near a source of
vibration
When installed in a place receiving
corrosive gases
Others
CAUTION
YASKAWA
200V
SERVOPACK
SGDP−
MODE/SET
DATA/
POWER
CHARGE
C
L1
N
3
L2
L3
1
2
C
N
1
L1C
L2C
B1
B2
B3
C
N
U
2
V
W
Situation
Design the control panel size, unit layout, and cooling method
so that the temperature around the periphery of the SERVO-
PACK does not exceed 55°C.
Suppress radiation heat from the heating unit and a temperature
rise caused by convection so that the temperature around the
periphery of the SERVOPACK does not exceed 55°C.
Install a vibration isolator underneath the SERVOPACK to
prevent it from receiving vibration.
Corrosive gases do not immediately affect the SERVOPACK
but will eventually cause contactor-related devices to malfunc-
tion. Take appropriate action to protect against corrosive gases.
Avoid installation in a hot and humid place or where excessive
dust or iron powder is present in the air.