ABB PowerValue RT G2 User Manual page 33

Ups 5-10 kva ul
Table of Contents

Advertisement

5 O P E R AT I O N
05: Others setting
Interface
O t h e r s :
H o t S t a n d b y :
A u d i b l e M u t e :
L a n g u a g e :
> > >
O t h e r s :
B a t M u t e :
F a u l t M u t e :
B y p a s s M u t e :
> > >
O t h e r s :
R e d u n d a n c y : 0 0
T o t a l P o w e r : 0 0
S t a n d a r d M o d e :
F a c t o r y R e s e t
Y Y i i _ _ L L i i u u
2 2 0 0 2 2 2 2 - - 0 0 1 1 - - 2 2 1 1
< < <
Y Y i i _ _ L L i i u u
2 2 0 0 2 2 2 2 - - 0 0 1 1 - - 2 2 1 1
Y Y i i _ _ L L i i u u
2 2 0 0 2 2 2 2 - - 0 0 1 1 - - 2 2 1 1
Description
1. Hot standby (only available or effective on bypass mode and
standby mode):
Enable: Hot standby function is enabled. It means that the current UPS is set to be host
of hot standby system, and it will automatically restart after AC recovery even without
battery connected.
D i s a b l e
Disable: Hot standby function is disabled. The UPS is running at normal mode and can't
restart without battery.
D i s a b l e
The default setting is Disable .
E n g l i s h
2. Audible Mute (available or effective for all mode):
Enable: It is to mute the buzzer.
Disable: It is to enable the buzzer when UPS have alarms or UPS is working in bypass
mode or battery mode.
The default setting is Disable .
3. Language (available or effective for all mode):
D i s a b l e
English: All interface will show in English
4. Bat Mute (available or effective on all mode):
D i s a b l e
Enable: It is to mute the buzzer when UPS is in battery mode.
D i s a b l e
Disable: It is to enable the buzzer when UPS is in battery mode.
The default setting is Disable .
5. Fault Mute (available or effective on all mode):
Enable: It is to mute the buzzer when UPS is in fault mode.
Disable: It is to enable the buzzer when UPS is in fault mode.
The default setting is Disable .
6. Bypass Mute (available or effective on all mode):
Enable: It is to mute the buzzer when UPS is in bypass mode.
E n a b l e
Disable: It is to enable the buzzer when UPS is in bypass mode.
The default setting is Disable .
7. Redundancy (available or effective on all mode): It is to set the quantity of redundant
UPS module. The setting range is 0~9. The setting quantity must be less than the total
number of UPS modules in the system. The default value is 0.
8. Total Power (available or effective on all mode): It is to set parallel number of power
modules for whole system.
9. Standard Mode(only available or effective on bypass mode and standby mode):
Enable: It is a compatible mode for dynamo.
Disable: It is a normal mode.
The default setting is Enable .
10. Factory Reset (only available or effective on bypass mode and standby mode):
Restore to factory default setting.
33