Filling Powder Chemicals By Using Turbofiller - Hardi ALPHA evo EcoDrive TWIN FORCE Instruction Book

Table of Contents

Advertisement

5 - Operation
DANGER! In order to avoid spray liquid hitting the operator, do not press the lever, unless the multi-hole nozzle is
covered by a container, as spray liquid may otherwise hit the operator!
μ
ATTENTION! The rinsing device uses spray liquid to rinse containers for concentrated chemicals. Before disposal,
always rinse the chemical containers with clean water several times, until they are clean.
• Flush the TurboFiller with clean water from the rinsing tank. The TurboFiller suction valve must be open for at least 20
seconds after the rinse water is no longer visible in the hopper, in order to empty the transfer hoses completely into
the main tank.
μ
ATTENTION! If not flushed with clean water, the hopper rinsing device uses spray liquid for rinsing the hopper!
Cleaning the TurboFiller must always be done, when the spray job is ended, and together with cleaning the entire
sprayer. A cleaning after the last filling, and before spraying, does not ensure a clean TurboFiller!
• Close the TurboFiller suction valve, when the hopper has been rinsed. Close the lid.
Turn the AgitationValve towards "Agitation".

Filling powder chemicals by using TurboFiller

• Fill the main tank at least 1/2 with water (unless otherwise stated
on the chemical container label).
• Turn the handle of the suction valve towards "suction from Main
tank". Turn pressure Smart valve towards ''Pressure
draining/Turbofiller' ' . Turn the Agitation Valve towards '' A gitation' ' if
required. Close remaining valves
μ
ATTENTION! For increased suction from Turbofiler the Agitation Valve can be kept closed
÷
NOTE! If filling water from an external tank, this can be continued while doing the next steps.
DANGER! Before turning Pressure SmartValve to "Pressure draining/TurboFiller" it is very important to be sure that the
quick coupler lid is correct and completely mounted to the filling stud into its locked position. Failure to do so may
cause risk of contamination and injury from quick coupler lid being "shot" off when pressurized! If not possible to
mount lid completely, lubricate the rubber seal and the grip hooks.
• Engage the diaphragm pump and set PTO revolutions.
• Open TurboFiller lid. Measure the correct quantity of chemical and fill it into the hopper.
• Measure the correct amount of powdered chemical and sprinkle it into the hopper as fast as the transfer device can
flush it down. The TurboFiller suction valve must be open for at least 20 seconds after the chemical is no longer visible
in the hopper in order to completely empty the transfer hoses into the main tank.
84
!
50%
!

Advertisement

Table of Contents
loading

Table of Contents