WARNING! Do not let the filling hose enter the tank. Keep it
outside the tank, pointing towards the filling hole. If the hose is
led into the tank, and the water pressure drops at the water
supply plant, chemicals may be sucked back and contaminate
the water supply lines, supply plant and supply well.
±
WARNING! The water supply line should be provided with a check
valve as additional safety precaution. Follow local legislation in force at any time.
±
WARNING! The water supply should be provided with a water meter to avoid spillage by over-filling. Follow local
legislation in force at any time.

External Filling device

The External Filling Device is operated as follows:
• Remove cover and connect suction hose to Suction Manifold.
• Turn handle on External Filling Device valve towards Filling Device.
• Turn pressure Smart valve to ''Main tank'' or ''Spraying / Turbofiller''
and close the suction valve.
• Engage the diaphragm pump and set PTO revolutions.
• The tank is now filled with water. Keep an eye on the liquid level
indicator.
• Turn handle on Suction Manifold away from Filling Device to
discontinue filling process. Then disengage pump.
• Disconnect suction hose and replace cover
• Turn the suction valve to ''Main tank'' .
DANGER! Avoid contamination or personal injury. Do not open suction valve towards Suction Filling Device, unless
the pump is running and the filling hose is connected. If this valve is opened without the pump running, liquid will
stream out of the coupler.
±
WARNING! Do not leave the sprayer whilst filling the tank, and keep an eye on the level indicator in order NOT to
overfill the tank.
±
WARNING! If suction hose/filter is carried on the sprayer during spraying, it can be contaminated by spray drift which
will be transferred to lake/river when filling
μ
ATTENTION! Observe local legislation regarding use of filling device. In some areas, it is prohibited to fill from open
water reservoirs (lakes, rivers etc.). It is strongly recommended only to fill from closed reservoirs (mobile water tanks
etc.) to avoid contamination.