Filling Powder Chemicals By Hardi Turbofiller (Optional) - Hardi NAVIGATOR PRO Original Instruction Book

Table of Contents

Advertisement

5 - Operation

Filling powder chemicals by HARDI TurboFiller (optional)

1. Fill the main tank at least 1/2 with water (unless otherwise stated
on the chemical container label). See section "Filling of water".
2. Turn the handle of the suction valve towards "suction from Main
tank". Turn pressure SmartValve towards "Pressure
draining/TurboFiller". Turn the AgitationValve towards "Agitation" if
required. Close remaining valves.
μ
ATTENTION! For increased suction from the TurboFiller the
AgitationValve can be kept closed.
DANGER! Before turning Pressure SmartValve to "Pressure
draining/TurboFiller" it is very important to be sure that the quick
coupler lid is correct and completely mounted to the filling stud into its locked position. Failure to do so may cause
risk of contamination and injury from quick coupler lid being "shot" off when pressurized! If not possible to mount lid
completely, lubricate the rubber seal and the grip hooks.
3. Engage the pump and set P.T.O. speed at 540 r/min or 1000 r/min (depending on pump model).
4. Open TurboFiller lid. Open TurboDeflector valve and TurboFiller suction valve.
5. Measure the correct quantity of chemical and sprinkle it into the hopper as fast as the transfer device can flush it down.
DANGER! Always wear face shield and other appropriate personal safety equipment when filling chemicals.
6. If the chemical container is empty, it can be rinsed by the Chemical Container Cleaning device. Place the container
over the multi-hole nozzle and push the upper lever to the left of the TurboFiller.
DANGER! In order to avoid spray liquid hitting the operator, do not press lever unless the multi-hole nozzle is covered
by a container as spray liquid may otherwise hit the operator.
μ
ATTENTION! Rinsing device uses spray liquid to rinse containers for concentrated chemicals. Always rinse the
chemical containers with clean water several times until they are clean before disposal.
7. Close TurboFiller suction valve when the hopper has been rinsed.
8. Close the TurboFiller lid.
μ
ATTENTION! The hopper rinsing device is using spray liquid for rinsing the hopper for concentrated chemical!
Cleaning the TurboFiller must always be done when the spray job is ended and together with the entire sprayer - a
cleaning after the last filling and before spraying the last tankful does not ensure a clean TurboFiller!
9. If closed, turn the AgitationValve towards "Agitation".
10. When the spray liquid is well agitated, turn handle of the pressure
SmartValve towards "Spraying" position. Keep P.T.O. engaged so
the spray liquid is continuously agitated until it has been sprayed
on the crop.