Hardi ALPHA evo EcoDrive TWIN FORCE Instruction Book page 85

Table of Contents

Advertisement

DANGER! Always wear face shield and other appropriate personal safety equipment, when filling chemicals.
μ
ATTENTION! The scale in the hopper can only be used, if the sprayer is parked on level ground! It is recommended to
use a measuring jug for best accuracy.
• Open the vortex valve (2)
• Engage the hopper transfer device by opening the TurboFiller suction valve (3) then the valve (1) to transfer chemicals
to the main tank. The TurboFiller suction valve must be open for at least 20 seconds after the chemical is no longer
visible in the hopper, in order to empty the transfer hoses completely into the main tank.
DANGER! If the TurboFiller and the transfer hoses are not completely emptied, there is a risk of chemicals being
sucked out of the main tank!
DANGER! If the TurboFiller and the transfer hoses are not completely emptied, there is a risk of chemicals being
sucked out of the main tank!
• If the chemical container is empty, it can be rinsed by the Chemical Container Cleaning device. Place the container
over the multi-hole nozzle and push the container for cleaning.
DANGER! In order to avoid spray liquid hitting the operator, do not press the lever, unless the multi-hole nozzle is
covered by a container, as spray liquid may otherwise hit the operator!
μ
ATTENTION! The rinsing device uses spray liquid to rinse containers for concentrated chemicals. Always rinse the
chemical containers with clean water several times, until they are clean before disposal.
• Flush the TurboFiller with clean water from the rinsing tank. The TurboFiller suction valve must be open for at least 20
seconds after the rinse water is no longer visible in the hopper, in order to empty the transfer hoses completely into
the main tank.
μ
ATTENTION! If not flushed with clean water, the hopper rinsing device uses spray liquid for rinsing the hopper!
Cleaning the TurboFiller must always be done, when the spray job is ended, and together with cleaning the entire
sprayer. A cleaning after the last filling, and before spraying, does not ensure a clean TurboFiller!
• Close the TurboFiller suction valve, when the hopper has been rinsed. Close the lid.
• If closed, turn the AgitationValve towards "Agitation".
5. When the spray liquid is well agitated, turn handle of the pressure
SmartVvalve towards "Spraying" position. Keep PTO engaged, so
that the spray liquid is continuously agitated, until it has been
sprayed on the crop.
5 - Operation
!