JP7
This Jumper is used for setting each axis EMG signal when the SW1 is set to ON, it
connects to EGND directly or connects to EMG/GDI11 by user wiring. The detail
content is as below (Fig. 1-7 or Fig. 1-8):
Fig 1-7 The EMG signal is connected to E_GND, directly. (Default setting)
Fig 1-8 the EMG signal is used by EMG/DI11
JP8 ~ JP9
This jumper (JP8 ~ JP9) is used for choosing the RS232 of the computer connect
with any axis of DN-8368MB of J2S servo-driver. And they (JP8 and JP9) must be
set at the same time. The detail content is as below (Fig. 1-9):
Fig 1-9 with what axis link set up RS232 (Default setting is for 0/3-axis)
http://www.icpdas.com
DN-8368MB User Manual
V 1.0 17 