5.3.5 Alarm Setting

Downlink Signal Low: Allows the user to specify how low the signal can be before triggering a "Downlink
Signal Low" soft-fail alarm
Downlink Signal Not Detected: Allows the user to specify how low the signal can be before triggering a
"Downlink Signal Not Detected" soft-fail alarm
Downlink RF Power: Allows the user to set a maximum deviation value for the downlink RF power
-
For example, if the input signal is -50 dBm and the gain is set to 60 dB, the expected output power
should be 10 dBm. If the Downlink RF Power alarm value is set to 6dB, then if the output power is
below 4 dBm, then this will trigger a soft-fail alarm
VSWR ON: Allows the user to enable/disable the VSWR alarm check
Advanced RF Technologies, Inc.

Figure 5-16 Alarm Threshold Setting