Click OK to reboot the repeater or click Cancel to exit out
Factory Setting: Resets the repeater to the original factory settings

Figure 5-13 Pop-up message when Factory Setting button is pressed

5.3.3 SNMP Trap

SNMP Trap ON – Enables or Disables SNMP traps from being sent out when an alarm is triggered.
Heartbeat Periodic Time [min] – Specifies the amount time between heartbeats

5.3.4 Gain Control

Downlink Gain/Uplink Gain: Allows the UL gain to be adjusted manually when ALC is OFF
DL Output ALC Level: Prevents the output power from exceeding the specified value
DL Output ALC Offset: When the incoming signal level increases, the system will not adjust the
attenuation levels until the delta reaches the level specified
DL /UL Gain Balance ON: Allows the user to enable or disable the gain balance. When gain balance is
enabled, the delta value between the downlink and uplink gains remain constant
Advanced RF Technologies, Inc.

Figure 5-12 Pop-up message when Reboot button is pressed

Figure 5-14 SNMP Trap

Figure 5-15 Gain Control Setting