METER INSTRUCTION
6.2 Introduction
6.2.1. Introduction to the display interface
Examples of display interface:
Table 4 Partial display interface diagram
Current forward active energy
12.34kWh
Current total power 1.234kW
Phase A voltage 123.4V
NOTE: The above is just a part of the display interface. The display mode of other
interfaces is similar to the above figure. You can determine the display meaning
according to the information displayed on the interface.
22
Current reversing active energy
12.34kWh
Current positive active power
demand 1.234kW
Phase A current 12.34A
23
6.2.2. Introduction to programming interface
1.Press "SET" and the screen shows "PASS"
2.Press "ENT" and the screen shows "0000"
3.Input "0001" as the password and press "ENT"
4.Set the parameters
5.After settings, press "SET" and the screen shows "SAVE"
6.Select "YES" and press "ENT" to save the settings
NOTE: The above list is the key sequence interface when the ADL3000 is equipped
with all functions. If there is no customized function, there is no relevant display
interface. The displayed values are all primary data. Please Make sure that the set
ratio is consistent with the actual ratio.
6.3 Meter setting
Main interface
SET
SET
PASS
Enter
SET
0001
Enter
BUS
Enter
SET
Addr
Enter
SET
Enter the serial
number of
themeter
Figure 6-2 Flow chart of meter setting
METER INSTRUCTION
Yes
Enter
Discard data
No
Enter
Enter
Discard data
SAVE
SET
SET
SET
SYS