3.1 Connecting the AC Power Cable

Cabling the System

This chapter contains procedures for cabling the system to the network and
supplying AC power.
To prepare the AC power cord:
1. Locate the gray plastic key that is in the accessory box.
2. Turn the system key switch to
See Figure 3-1.
3. Ensure that the AC distribution unit switch is set to Off.
This switch is at the rear of the cabinet. See Figure 3-2.
Warning – Risk of Electric Shock. Turn off AC power at the AC distribution
unit before you insert or remove boards and disk drives. For proper grounding
of the system, do not disconnect the AC power cord from its receptacle.
4. If the rear screen is still in place, remove it now.
Remove two screws near the top of the screen. See Figure 3-3. Tilt the screen
out and lift the screen free of the chassis. Set the screen aside.
5. Take out the AC power cord that is coiled inside the server cabinet.
(the standby position).