5 OPERATION

5
OPERATION
5.1

Overview

General safety regulations for handling the equipment can be found in the chapter
"Safety." Read it before you start using the equipment.
5.2

Connections and control devices

1.
Mains power supply switch, I/O
2.
Knob for selecting electrode type
3.
Knob for inductance (MIG/MAG) and
arc force (MMA)
4.
Display, current (A) and voltage (V)
5.
Knob for setting: SMAW/GTAW: current
(A) and Gouging: voltage (V)
6.
Process selection knob (SMAW,
GMAW, GTAW, Mobile feed, Gouging)
7.
Circuit breaker, 10 A, 42 V
8.
Connection for wire feed unit
NOTE!
Welding terminals, positive (+) and negative (-), are lug type connectors and adapter
cables are required to connect lug to OKC for 70 mm
0463 730 001
9.
Connection for remote control unit
10.
Lug connection (-): MIG/MAG: Return
cable TiG: Welding torch MMA: Welding
cable or return cable Gouging: Return
cable
11.
Lug connection (+): MIG/MAG: Welding
cable TiG: return cable MMA: Welding
cable or return cable Gouging: Welding
torch
12.
Voltage selector switch
13.
Power socket for grinding machine,
CO
 heater, lighting (115 VAC)
2
14.
Circuit breaker, 20 A, 115 VAC
15.
Connection for cooler power supply
16.
Connection for mains power supply
2
and 95 mm
- 19 -
2
cables.
© ESAB AB 2021