4 INSTALLATION
WARNING!
Secure the equipment - particularly
if the ground is uneven or sloping.
4.3

Location

Position the welding power source such that its cooling air inlets and outlets are not
obstructed.
 
4.4

Main supply

NOTE!
Mains supply requirements
This equipment complies with IEC 61000-3-12 provided that the short-circuit power
is greater than or equal to S
and the public system. It is the responsibility of the installer or user of the equipment
to ensure, by consultation with the distribution network operator if necessary, that
the equipment is connected only to a supply with a short-circuit power greater than
or equal to S
scmin
Make sure that the welding power source is connected to the correct supply voltage and that
it is protected by the correct fuse rating. A protective ground connection must be made in
accordance with regulations.
1.
Rating plate with supply connection
data
0463 730 001
at the interface point between the user's supply
scmin
. Refer to the technical data in the TECHNICAL DATA chapter.