Recommended Fuse Sizes And Minimum Cable Area; Warrior 750I Cc/Cv; Supply From Power Generators - ESAB Warrior 750i CC/CV Instruction Manual

Hide thumbs Also See for Warrior 750i CC/CV:
Table of Contents

Advertisement

4 INSTALLATION
4.4.1
Recommended fuse sizes and minimum cable area Warrior 750i CC/CV
Mains voltage
Mains cable area
Phase current I
eff
Fuse
anti-surge
type C MCB
Mains voltage
Mains cable area
Phase current I
eff
Fuse
anti-surge
type C MCB
Mains voltage
Mains cable area
Phase current I
eff
Fuse
anti-surge
type C MCB
NOTE!
The power cable areas and fuse sizes as shown above are in accordance with
Swedish regulations. Use the power source in accordance with the relevant national
regulations.
4.4.2

Supply from power generators

The power source can be supplied from different types of generators. However, some
generators may not provide sufficient power for the welding power source to operate
correctly. Generators with Automatic Voltage Regulation (AVR) or with an equivalent or better
type of regulation, with rated power ≥75 kW, are recommended.
0463 730 001

Warrior 750i CC/CV

380 V 3~ 50/60 Hz
2
4x16 mm
65 A
80 A
Warrior 750i CC/CV
415 V 3~ 50/60 Hz
2
4x16 mm
60 A
63 A
Warrior 750i CC/CV
460 V 3~ 50/60 Hz
2
4x12 mm
54 A
63 A
- 16 -
400 V 3~ 50/60 Hz
2
4x16 mm
62 A
63 A
440 V 3~ 50/60 Hz
2
4x12 mm
56 A
63 A
575 V 3~ 50/60 Hz
2
4x8 mm
43 A
63 A