3 TECHNICAL DATA

3
TECHNICAL DATA
Working voltage
Mains supply S
scmin
Mains supply Z
max
Primary current
I
GMAW - MIG
max.
I
GTAW - TIG
max.
I
SMAW - MMA
max.
I
Gouging
max.
No load power in energy-saving
mode 6.5 min. after welding
Setting range for all modes
GMAW - MIG flat characteristic
GTAW - TIG drooping
characteristic
SMAW - MMA drooping
characteristic
Gouging
Permissible load at GMAW
60% duty cycle
100% duty cycle
Permissible load at GTAW
60% duty cycle
100% duty cycle
Permissible load at SMAW
60% duty cycle
100% duty cycle
Gouging
35% duty cycle
60% duty cycle
100% duty cycle
Power factor at maximum current
GMAW
GTAW
SMAW
Gouging
Efficiency at maximum current
0463 730 001
Warrior 750i CC/CV
380–575 V, ±10%, 3~ 50/60 Hz
5.4 MVA
0.0319 ohm
380 V
400 V
415 V
70 A
66 A
64 A
55 A
52 A
50 A
70 A
66 A
64 A
70 A
66 A
64 A
34 W
16 A/15 V – 820 A/44 V
10 A/10 V–820 A/34 V
15 A/15 V–820 A/44 V
100 A/18 V–820 A/44 V
820 A/44 V
750 A/44 V
820 A/34 V
750 A/34 V
820 A/44 V
750 A/44 V
850 A/44 V
820 A/44 V
750 A/44 V
0.91
- 12 -
440 V
460 V
575 V
60 A
58 A
46 A
47 A
45 A
36 A
60 A
58 A
46 A
60 A
58 A
46 A
© ESAB AB 2021