Troubleshooting - ESAB Warrior 750i CC/CV Instruction Manual

Hide thumbs Also See for Warrior 750i CC/CV:
Table of Contents

Advertisement

9 TROUBLESHOOTING

9
TROUBLESHOOTING
Try these recommended checks and inspections before sending for an authorized service
technician.
Type of fault
No display.
Overheating on welding/return cable
connections.
No arc.
The welding current is interrupted during
welding.
The overheating protection trips frequently.
Poor welding performance.
0463 730 001
Corrective action
Check that the supply is available and
the main switch is turned ON.
Check the supply fuses/MCB. (See the
"Mains supply" section).
Press the resettable fuse near to
voltage selector switch in the rear side
of power source.
Check the electrical connections and
ensure that the welding cables are
tightened properly to the copper bars.
Check the size of the welding cable.
(See the "Connection of welding and
return cables" section.)
Check that the main power supply
switch is turned on.
Check that the mains, welding, and
return cables are correctly connected.
Check that the correct current value is
set.
Check the electrical power supply
fuses.
Check whether the overloading
protection has tripped (indicated on the
front).
Check the electrical power supply
fuses.
Check that the return cable is correctly
fastened.
Make sure that you are not exceeding
the rated data for the power source (i.e.
that the unit is not being overloaded).
Check that the welding and return
cables are correctly connected.
Check that the correct current value is
set.
Check that the correct wire or electrode
is used.
Check the electrical power supply
fuses.
Check the gas pressure in the
equipment connected to the power
source.
- 29 -