Chapter 5 Device Settings; Set Study Mode - HIKVISION DS-K3B961TX-L User Manual

Swing barrier
Table of Contents

Advertisement

After installation and wiring completed, the turnstile will study the open and closed position
automatically.
After the learning, the turnstile is in the normal mode. You can also set the turnstile to study
mode, normal mode, and pair the keyfob, initialize the hardware via the main user extended
interface board (middle/right pedestal).
Study Mode
Study the closed position.
Normal Mode
The device will work properly.
Keyfob Pairing
Pair the keyfob and the turnstile.

5.1 Set Study Mode

Enter the study mode through DIP switching to set the closed position of the device barrier.
Steps
1. Set The No.1 of the 4-digit DIP Switch on the main user extended interface board to ON by
referring the following figure to enter the study mode.
2. Adjust the closed position of the barrier.
3. Power on the device.
The device will remember the current position (closed position) automatically.
4. Power off the device.
DS-K3B961TX Series Swing Barrier User Manual

Chapter 5 Device Settings

Figure 5-1 Study Mode