Summary of Contents for HIKVISION DS-K3B601S Series

  • Page 1 DS-K3B601SX Series Swing Barrier User Manual...
  • Page 2 WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES,...
  • Page 3 During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method;...
  • Page 4 DS-K3B601SX Series Swing Barrier User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 5 DS-K3B601SX Series Swing Barrier User Manual under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points.
  • Page 6 DS-K3B601SX Series Swing Barrier User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions: Dangers: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage.
  • Page 7 DS-K3B601SX Series Swing Barrier User Manual • Do not ingest battery, Chemical Burn Hazard. This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep new and used batteries away from children.
  • Page 8 DS-K3B601SX Series Swing Barrier User Manual • Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs. •...
  • Page 9 DS-K3B601SX Series Swing Barrier User Manual Available Models Product Name Model Description Swing Barrier DS-K3B601SX-L Left Pedestal DS-K3B601SX-M Middle Pedestal DS-K3B601SX-R Right Pedestal viii...
  • Page 10: Table Of Contents

    DS-K3B601SX Series Swing Barrier User Manual Contents Chapter 1 Overview ........................1 1.1 Introduction ........................... 1 1.2 Main Features ........................1 Chapter 2 System Wiring ......................2 Chapter 3 Installation ......................... 8 3.1 Disassemble Pedestals ......................8 3.2 Install Pedestals ........................8 Chapter 4 General Wiring ......................
  • Page 11 DS-K3B601SX Series Swing Barrier User Manual 5.4 Switch to RS-485/RS-232 Mode ................... 31 5.5 Switch Relay Output Mode (NO/NC) ..................31 5.5.1 Barrier Control Relay Output Mode ................31 5.5.2 Alarm Relay Output Mode (NO/NC) ................32 Chapter 6 Activation ......................... 33 6.1 Activate via SADP .........................
  • Page 12 DS-K3B601SX Series Swing Barrier User Manual 7.4.11 Configure Resident Information ................55 7.4.12 Configure Additional Information ................56 7.4.13 Import and Export Person Identify Information ............56 7.4.14 Import Person Information ..................56 7.4.15 Import Person Pictures ..................... 57 7.4.16 Export Person Information ..................58 7.4.17 Export Person Pictures ....................
  • Page 13 DS-K3B601SX Series Swing Barrier User Manual 7.8.3 Configure Device Actions for Card Swiping ..............85 7.9 Door Control ........................86 7.9.1 Control Door Status ..................... 86 7.9.2 Check Real-Time Access Records ................88 7.10 Event Center ........................88 7.10.1 Enable Receiving Event from Devices ............... 88 7.10.2 View Real-Time Events ....................
  • Page 14 DS-K3B601SX Series Swing Barrier User Manual Appendix E. Error Code Description ..................108 Appendix F. Communication Matrix and Device Command ............. 109 xiii...
  • Page 15: Chapter 1 Overview

    DS-K3B601SX Series Swing Barrier User Manual Chapter 1 Overview 1.1 Introduction The swing barrier with two barriers and 20 IR lights is designed to detect unauthorized entrance or exit. By adopting the swing barrier integratedly with the access control system, person should authenticate to pass through the lane via swiping IC or ID card, scanning QR code, etc.
  • Page 16: Chapter 2 System Wiring

    DS-K3B601SX Series Swing Barrier User Manual Chapter 2 System Wiring The preparation before installation and general wiring. Steps Note • The device should be installed on the concrete surface or other non-flammable surfaces. • If the installation area is too close to the wall, make sure the distance between the pedestal and the wall should be no more than 10 mm, or you cannot open the pedestal's top panel.
  • Page 17 DS-K3B601SX Series Swing Barrier User Manual Figure 2-2 Dimension (1850 mm) 1. Draw a central line on the installation surface of the left or right pedestal. 2. Draw other parallel lines for installing the other pedestals. Note The distance between the nearest two line is L+200 mm. L represents the lane width. 3.
  • Page 18 DS-K3B601SX Series Swing Barrier User Manual Figure 2-3 Hole Position Diagram 4. Bury cables. Each lane buries 1 network cable and 1 high voltage cable. For details, see the system wiring diagram below.
  • Page 19 DS-K3B601SX Series Swing Barrier User Manual Figure 2-4 System Wiring Diagram (General Wiring) Note • The supplied interconnecting cable length is 5.5 m. • The suggested inner diameter of the low voltage conduit is larger than 30 mm. • If you want to bury both of the AC power cord and the low voltage cable at the entrance, the two cables should be in separated conduits to avoid interference.
  • Page 20 DS-K3B601SX Series Swing Barrier User Manual Figure 2-5 Wire Face Recognition Terminal Note • The supplied interconnecting cable length is 5.5 m. • The left pedestal and the middle pedestal should bury interconnecting cables for connecting the face recognition terminal. •...
  • Page 21 DS-K3B601SX Series Swing Barrier User Manual • The external AC power cord should be double-insulated. • The network cable must be CAT5e or the network cable has better performance. And the suggested network cable length should be less than 100 m.
  • Page 22: Chapter 3 Installation

    DS-K3B601SX Series Swing Barrier User Manual Chapter 3 Installation 3.1 Disassemble Pedestals Before installation, you should use the key to open the pedestals. View the pictures below to find the lock holes. Figure 3-1 Lock Holes 3.2 Install Pedestals Before You Start Prepare for the installation tools, check the device and the accessories, and clear the installation base.
  • Page 23 DS-K3B601SX Series Swing Barrier User Manual Note Make sure the installation holes on the pedestals and the base are aligned with each other. 4. Secure the pedestals with expansion bolts. Note • Do not immerse the pedestal in the water. In special circumstances, the immersed height should be no more than 150 mm.
  • Page 24: Chapter 4 General Wiring

    DS-K3B601SX Series Swing Barrier User Manual Chapter 4 General Wiring 4.1 Components Introduction By default, basic components of the turnstile are connected well. The pedestals can communicate by wiring the interconnecting cables. And the turnstile supports wiring the AC electric supply for the whole system’s power supply.
  • Page 25: Wiring Electric Supply

    DS-K3B601SX Series Swing Barrier User Manual Figure 4-2 IR Sending/Receiving Module Position Note If the turnstile contains two lanes, standing at the entrance position, the IR modules on the left pedestal are the IR sending modules. The IR modules on the right pedestal are the IR receiving modules.
  • Page 26: Wire Interconnecting Cable

    DS-K3B601SX Series Swing Barrier User Manual Note • The cable bare part should be no more than 8 mm. It is suggested that you can immerse the bare part into the liquid tin. If possible, wear an insulation cap at the end of the bare cable. Make sure there’s no bare copper or cable after the wiring.
  • Page 27: Wire Network Switch

    DS-K3B601SX Series Swing Barrier User Manual Figure 4-3 Cable Hole of Interconnecting Cable Follow the instructions below to connect the interconnecting cable. Figure 4-4 Connect Interconnecting Cable 4.4 Wire Network Switch Connect the network cable and the network switch. Steps 1.
  • Page 28 DS-K3B601SX Series Swing Barrier User Manual Figure 4-5 Open Top Cover The network switch's position is shown as follows.
  • Page 29: Terminal Description

    DS-K3B601SX Series Swing Barrier User Manual Figure 4-6 Network Switch Position 2. Lead out 12 V power supply from the main switch and connect it to the network switch's power interface. 3. Connect the network cable with the network switch. 4.5 Terminal Description The lane controller contains main lane controller and sub lane controller, which controls the IR beams, motor, and other components' work.
  • Page 30: Sub Control Board Terminal Description

    DS-K3B601SX Series Swing Barrier User Manual 4.5.2 Sub Control Board Terminal Description The sub lane control board contains interconnecting interfaces, BUS, motor encoder interface, debugging port, door closed position interface, seven-segment display, strip light interface (reserved), supercapacitor, power interface, and motor drive interface. The picture displayed below is the sub control board diagram.
  • Page 31: Access Control Board Terminal Description

    DS-K3B601SX Series Swing Barrier User Manual 4.5.3 Access Control Board Terminal Description Table 4-1 Access Control Board Terminal Description Access Controlling Board Terminal Description Power Output 1 +12 V Power Output Grounding Wiegand Card Indicator of Card Reader Control Output (Invalid Card Reader 1 Output) Indicator of Card Reader Control Output (Valid Card...
  • Page 32 DS-K3B601SX Series Swing Barrier User Manual Access Controlling Board Terminal Description Card Reader Buzzer Control Output Wiegand Head Read Data Input Data1 Wiegand Head Read Data Input Data0 Grounding RS-485 Interface Grounding RS-485 B- Connect to Card Reader RS485- RS-485 B+ Connect to Card Reader RS485+ Grounding RS-485 C-...
  • Page 33 DS-K3B601SX Series Swing Barrier User Manual Access Controlling Board Terminal Description Door Lock (Relay) Door 1 Relay Output (Dry Contact) Door 2 Relay Output (Dry Contact) Alarm Output NO/NC1 Alarm Output Relay 1 (Dry Contact) COM1 NO/NC2 Alarm Output Relay 2 (Dry Contact) COM2 NO/NC3 Alarm Output Relay 3 (Dry Contact)
  • Page 34: Access Control Board Serial Port Id Description

    DS-K3B601SX Series Swing Barrier User Manual 4.5.4 Access Control Board Serial Port ID Description You can use the jumper cap on the access control board to switch the interface communication mode. For details about switching between RS-232 and RS-485 communication type, see Switching RS-485/RS-232 Mode.
  • Page 35 Use the jumper cap to switch the serial port communication mode with the lane controller. By default, the interface is wired and it is in RS-485 communication mode. If wiring other controllers (compatible with Hikvision communication protocol), use the jumper cap to switch between RS-485 and RS-232 communication mode.
  • Page 36 DS-K3B601SX Series Swing Barrier User Manual Figure 4-8 Interface and Corresponded UART No.
  • Page 37: Wiring

    DS-K3B601SX Series Swing Barrier User Manual 4.5.5 RS-485 Wiring Note • There are four RS-485 interfaces, which are for connecting ID card reader, IC card reader, QR code scanner, fingerprint and card reader, card recycler, fingerprint reader, and face recognition terminal.
  • Page 38 DS-K3B601SX Series Swing Barrier User Manual...
  • Page 39: Wiegand Wiring

    DS-K3B601SX Series Swing Barrier User Manual 4.5.7 Wiegand Wiring Note Connect the OK/ERR/BZ if the access controller should control the LED and buzzer of the Wiegand card reader. 4.5.8 Barrier Control Wiring By default, the barrier has connected with the access control board. The lane control board can control the barrier status.
  • Page 40 DS-K3B601SX Series Swing Barrier User Manual Entering Wiring Exiting Wiring...
  • Page 41: Alarm Output Wiring

    DS-K3B601SX Series Swing Barrier User Manual 4.5.9 Alarm Output Wiring Note For details about changing the relay output status via the jumper cap, see Alarm Relay Output Mode (NO/NC) .
  • Page 42: Chapter 5 Device Settings

    DS-K3B601SX Series Swing Barrier User Manual Chapter 5 Device Settings After installation and wiring completed, the turnstile will learn the open and closed position automatically. After the learning, the turnstile is in the normal mode. You can also set the turnstile to test mode, passing mode and memory mode, pair the keyfob, initialize the hardware, switching between RS-485 communication mode and RS-232 communication mode, and view relay output NO/NC diagram by setting the DIP switch on the access control board.
  • Page 43: Pair Keyfob (Optional)

    DS-K3B601SX Series Swing Barrier User Manual 4. Power off the device. 5. Set the No.1 switches of the 8-digit DIP Switch on the main control board by referring to the following figure. 6. Power on the device again. Note For details about the DIP switch value and meaning, see DIP Switch Description. The barrier will open automatically and turns back to the closed position.
  • Page 44: Initialize Device

    DS-K3B601SX Series Swing Barrier User Manual Note • Only one turnstile can pair the keyfob. If multiple turnstiles are in the pairing mode, the keyfob will select only one of them to pair. • For details about DIP switch value and meaning, see DIP Switch . 6.
  • Page 45: Switch To Rs-485/Rs-232 Mode

    DS-K3B601SX Series Swing Barrier User Manual Note Make sure no persons are in the lane when powering on the device. 5.4 Switch to RS-485/RS-232 Mode Take the Serial Port 4 and on the access control board as an example. If the Jumper cap's position is like the picture displayed below.
  • Page 46: Alarm Relay Output Mode (No/Nc)

    DS-K3B601SX Series Swing Barrier User Manual Figure 5-4 Pin Appearance The jumper cap's position of barrier opening for entrance (NO) is as below: The jumper cap's position of barrier opening for exit (NO) is as below: The jumper cap's position of barrier closing for entrance (NC) is as below: The jumper cap's position of barrier closing for exit (NC) is as below: 5.5.2 Alarm Relay Output Mode (NO/NC) Alarm Relay Output Mode (NO):...
  • Page 47: Chapter 6 Activation

    • Get the SADP software from the supplied disk or the official website http:// www.hikvision.com/en/ , and install the SADP according to the prompts. • The device and the PC that runs the SADP tool should be within the same subnet.
  • Page 48: Activate Device Via Client Software

    DS-K3B601SX Series Swing Barrier User Manual Status of the device becomes Active after successful activation. 5. Modify IP address of the device. 1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP.
  • Page 49 DS-K3B601SX Series Swing Barrier User Manual three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you change your password regularly, especially in the high security system, changing the password monthly or weekly can better protect your product.
  • Page 50: Chapter 7 Client Software Configuration

    DS-K3B601SX Series Swing Barrier User Manual Chapter 7 Client Software Configuration 7.1 Configuration Flow of Client Software Follow the flow diagram below to configure on the client software. Figure 7-1 Flow Diagram of Configuration on Client Software 7.2 Device Management The client supports managing access control devices and video intercom devices.
  • Page 51: Add Device

    DS-K3B601SX Series Swing Barrier User Manual 7.2.1 Add Device The client provides three device adding modes including by IP/domain, IP segment, and ISUP protocol. The client also supports importing multiple devices in a batch when there are large amount of devices to be added. Add Online Device The active online devices in the same local subnet with the client software will be displayed on the Online Device area.
  • Page 52 DS-K3B601SX Series Swing Barrier User Manual Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
  • Page 53 DS-K3B601SX Series Swing Barrier User Manual Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
  • Page 54 DS-K3B601SX Series Swing Barrier User Manual Enter the device password. Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
  • Page 55 DS-K3B601SX Series Swing Barrier User Manual 3. Click Add to open the Add window. 4. Select IP Segment as the adding mode. 5. Enter the required information. Start IP Enter a start IP address. End IP Enter an end IP address in the same network segment with the start IP. Port Enter the device port No.
  • Page 56 DS-K3B601SX Series Swing Barrier User Manual Import Devices in a Batch You can add multiple devices to the client in a batch by entering the device parameters in a pre- defined CSV file. Steps 1. Enter the Device Management module. 2.
  • Page 57: Reset Device Password

    DS-K3B601SX Series Swing Barrier User Manual 7. Click Add to import the devices. 7.2.2 Reset Device Password If you forgot the password of the detected online devices, you can reset the device password via the client. Steps 1. Enter Device Management page. 2.
  • Page 58: Add Group

    DS-K3B601SX Series Swing Barrier User Manual 7.3.1 Add Group You can add group to organize the added device for convenient management. Steps 1. Enter the Device Management module. 2. Click Device Management → Group to enter the group management page. 3.
  • Page 59: Remove Resources From Group

    DS-K3B601SX Series Swing Barrier User Manual Before You Start Import the resources to group. Steps 1. Enter the Device Management module. 2. Click Device Management → Group to enter the group management page. All the added groups are displayed on the left. 3.
  • Page 60: Configure Basic Information

    DS-K3B601SX Series Swing Barrier User Manual Note Up to 10 levels of organizations can be added. 4. Optional: Perform the following operation(s). Edit Organization Hover the mouse on an added organization and click to edit its name. Delete Hover the mouse on an added organization and click to delete it.
  • Page 61: Issue A Card By Local Mode

    DS-K3B601SX Series Swing Barrier User Manual Figure 7-2 Configure Basic Information Note Once validity period expired, the credentials and access control settings of the person will be invalid and the person will have no authorization to access the doors\floors. You can click Extend to extend the person's validity period for 1 month, 3 months, 6 months, or 1 year.
  • Page 62 DS-K3B601SX Series Swing Barrier User Manual Figure 7-3 Issue a Card by Local Mode 6. Set other related parameters. Card Enrollment Station Select the model of the connected card enrollment station. Note Currently, the supported card enrollment station models include DS-K1F100-D8, DS-K1F100- M, DS-K1F100-D8E, and DS-K1F180-D8E.
  • Page 63: Upload A Face Photo From Local Pc

    DS-K3B601SX Series Swing Barrier User Manual This field is only available when the model is DS-K1F100-D8, DS-K1F100-D8E, or DS-K1F180- D8E. If the card is M1 card, then you can enable the M1 Card Encryption function and select the sector of the card to encrypt. 7.
  • Page 64 DS-K3B601SX Series Swing Barrier User Manual Before You Start Make sure PC running the client has a camera or you have connected other USB camera to the PC. Steps 1. Enter Person module. 2. Select an organization in the organization list to add the person and click Add to enter Add Person window.
  • Page 65: Collect Face Via Access Control Device

    DS-K3B601SX Series Swing Barrier User Manual 7.4.6 Collect Face via Access Control Device When adding person, you can collect the person's face via access control device added to the client which supports facial recognition function. Steps 1. Enter Person module. 2.
  • Page 66: Collect Fingerprint Via Access Control Device

    DS-K3B601SX Series Swing Barrier User Manual Steps 1. Enter Person module. 2. Select an organization in the organization list to add the person and click Add. Note Enter the person's basic information first. For details about configuring person's basic information, refer to Configure Basic Information . 3.
  • Page 67: Configure Access Control Information

    DS-K3B601SX Series Swing Barrier User Manual 4. In the pop-up window, select the collection mode as Remote. 5. Select an added access control device or the enrollment station from the drop-down list. Note If you select the enrollment station, you should click Login, and set IP address, port No., user name and password of the device.
  • Page 68 DS-K3B601SX Series Swing Barrier User Manual Note Persons' PIN codes cannot be repeated. - Click Generate to randomly generate an unrepeated PIN code of 6 digits. Note If there are repeated PIN codes, a prompt will pop up on the client. The admin can generate a new PIN code to replace the repeated PIN code and notify related persons.
  • Page 69: Customize Person Information

    DS-K3B601SX Series Swing Barrier User Manual 7.4.10 Customize Person Information You can customize the person properties which are not pre-defined in the client according to actual needs, e.g., place of birth. After customizing, when add a person, you can enter the custom information to make the person information complete.
  • Page 70: Configure Additional Information

    DS-K3B601SX Series Swing Barrier User Manual 5. Confirm to add the person. - Click Add to add the person and close the Add Person window. - Click Add and New to add the person and continue to add other persons. 7.4.12 Configure Additional Information When adding person, you can configure the additional information for the person, such as person's identity type, identity No., country, etc., according to actual needs.
  • Page 71: Import Person Pictures

    DS-K3B601SX Series Swing Barrier User Manual Note • If the person has multiple cards, separate the card No. with semicolon. • Items with asterisk are required. • By default, the Hire Date is the current date. 7. Click to select the CSV/Excel file with person information from local PC. 8.
  • Page 72: Export Person Information

    DS-K3B601SX Series Swing Barrier User Manual 7.4.16 Export Person Information You can export the added persons' information to local PC as a CSV/Excel file. Before You Start Make sure you have added persons to an organization. Steps 1. Enter the Person module. 2.
  • Page 73: Get Person Information From Access Control Device

    DS-K3B601SX Series Swing Barrier User Manual 7.4.18 Get Person Information from Access Control Device If the added access control device has been configured with person information (including person details, fingerprint, and issued card information), you can get the person information from the device and import them to the client for further operations.
  • Page 74: Issue Cards To Persons In Batch

    DS-K3B601SX Series Swing Barrier User Manual 3. Select the person to move. 4. Click Change Organization. 5. Select the organization to move persons to. 6. Click OK. 7.4.20 Issue Cards to Persons in Batch The client provides a convenient way to issue cards to multiple persons in a batch. Steps 1.
  • Page 75: Set Card Issuing Parameters

    DS-K3B601SX Series Swing Barrier User Manual apply the changes to the device. After applying to device, these changes can take effect on the device. 7.4.22 Set Card Issuing Parameters The client provides two modes for reading a card's number: via card enrollment station or via the card reader of the access control device.
  • Page 76: Configure Schedule And Template

    DS-K3B601SX Series Swing Barrier User Manual Remote Mode: Issue Card by Card Reader Select an access control device added in the client and swipe the card on its card reader to read the card number. 7.5 Configure Schedule and Template You can configure the template including holiday and week schedule.
  • Page 77: Add Template

    DS-K3B601SX Series Swing Barrier User Manual • Move the cursor to the time duration and drag the time duration on the timeline bar to the desired position when the cursor turns to • Click the time duration and directly edit the start/end time in the appeared dialog. •...
  • Page 78: Set Access Group To Assign Access Authorization To Persons

    DS-K3B601SX Series Swing Barrier User Manual • Move the cursor to the time duration and drag the time duration on the timeline bar to the desired position when the cursor turns to • Click the time duration and directly edit the start/end time in the appeared dialog. •...
  • Page 79 DS-K3B601SX Series Swing Barrier User Manual Note You should configure the template before access group settings. Refer to Configure Schedule and Template for details. 5. In the left list of the Select Person field, select person(s) to assign access authority. 6.
  • Page 80: Configure Advanced Functions

    DS-K3B601SX Series Swing Barrier User Manual Note You can check Display Failure Only to filter the applying results. The selected persons in the applied access groups will have the authorization to enter/exit the selected doors/door stations with their linked card(s) or fingerprints. 9.
  • Page 81 DS-K3B601SX Series Swing Barrier User Manual Configure Parameters for Access Control Device After adding the access control device, you can configure its parameters. Steps 1. Click Access Control → Advanced Function → Device Parameter . Note If you can find Device Parameter in the Advanced Function list, Hover the cursor on the Advanced Function, and then Click to select the Device Parameter to be displayed.
  • Page 82 DS-K3B601SX Series Swing Barrier User Manual Configure Parameters for Door After adding the access control device, you can configure its access point door parameters. Steps 1. Click Access Control → Advanced Function → Device Parameter . 2. Select an access control device on the left panel, and then click to show the doors or floors of the selected device.
  • Page 83 DS-K3B601SX Series Swing Barrier User Manual Note • The duress code, super code, and dismiss code should be different. • The duress code, super password, and the dismiss code should be different from the authentication password. • The length of duress code, super password, and the dismiss code is according the device, usually it should contains 4 to 8 digits.
  • Page 84 DS-K3B601SX Series Swing Barrier User Manual If enabling the function, user can present card on the card reader. If disabling the function, the card reader for entrance cannot be used. OK LED Polarity/Error LED Polarity/Buzzer Polarity Set OK LED Polarity/Error LED Polarity/Buzzer LED Polarity of main board according to the card reader parameters.
  • Page 85 DS-K3B601SX Series Swing Barrier User Manual 4. Click OK. 5. Optional: Set the switch on the upper right corner to ON to trigger the alarm output. Configure Parameters for Lane Controller After adding the lane controller to the client, you can configure its parameters for passing through the lane.
  • Page 86: Configure Remaining Open/Closed

    DS-K3B601SX Series Swing Barrier User Manual Barrier Material Select the material of the barrier gate. You can select the barrier material from the drop- down list. Note The barrier material will affect the device working. Select a correct barrier material or the barrier may not open.
  • Page 87: Configure Multi-Factor Authentication

    DS-K3B601SX Series Swing Barrier User Manual • Move the cursor to the time duration and drag the time duration on the timeline bar to the desired position when the cursor turns to • Click the time duration and directly edit the start/end time in the appeared dialog. •...
  • Page 88 DS-K3B601SX Series Swing Barrier User Manual Before You Start Set access group and apply the access group to the access control device. For details, refer to Set Access Group to Assign Access Authorization to Persons . Perform this task when you want to set authentications for multiple cards of one access control point (door).
  • Page 89: Configure Custom Wiegand Rule

    DS-K3B601SX Series Swing Barrier User Manual Figure 7-9 Remotely Open Door Note You can check Offline Authentication to enable the super password authentication when the access control device is disconnected with the client. Local Authentication and Super Password Authentication by the access control device and by the super password. 4) Select the added person/card group in the left list below and it will be added to the Selected list on the right as the authentication group.
  • Page 90 DS-K3B601SX Series Swing Barrier User Manual Before You Start Wire the third party card readers to the device. Steps Note • By default, the device disables the custom wiegand function. If the device enables the custom Wiegand function, all wiegand interfaces in the device will use the customized wiegand protocol. •...
  • Page 91: Configure Card Reader Authentication Mode And Schedule

    DS-K3B601SX Series Swing Barrier User Manual Figure 7-10 Set Output Transformation Rule 2) Select rules on the left list. The selected rules will be added to the right list. 3) Optional: Drag the rules to change the rule order. 4) Click OK. 5) In the Custom Wiegand tab, set the rule's start bit, length, and the decimal digit.
  • Page 92 DS-K3B601SX Series Swing Barrier User Manual Figure 7-11 Select Card Reader Authentication Mode Note PIN refers to the PIN code set to open the door. Refer to Configure Access Control Information . 2) Check the modes in the Available Mode list and they will be added to the selected modes list.
  • Page 93: Configure First Person In

    DS-K3B601SX Series Swing Barrier User Manual Figure 7-12 Set Authentication Modes for Card Readers 6. Optional: Select a configured day and click Copy to Week to copy the same settings to the whole week. 7. Optional: Click Copy to to copy the settings to other card readers. 8.
  • Page 94: Configure Anti-Passback

    DS-K3B601SX Series Swing Barrier User Manual Note The remain open duration should be between 0 and 1440 minutes. By default, the remain open duration is 10 minutes. Disable Remaining Open after First Person Disable the function of first person in, namely normal authentication. Authorization by First Person All authentications (except for the authentications of super card, super password, duress card, and duress code) are allowed only after the first person authorization.
  • Page 95: Configure Device Parameters

    DS-K3B601SX Series Swing Barrier User Manual 4. Click of the selected first card reader in the Card Reader Afterward column to open the select card reader dialog. 5. Select the afterward card readers for the first card reader. Note Up to four afterward card readers can be added as afterward card readers for one card reader. 6.
  • Page 96: Configure Linkage Actions For Access Control

    DS-K3B601SX Series Swing Barrier User Manual • The configured parameters will be applied to the device automatically. • When you change the working mode or connection mode, the device will reboot automatically. Enable M1 Card Encryption M1 card encryption can improve the security level of authentication. Steps Note The function should be supported by the access control device and the card reader.
  • Page 97: Configure Device Actions For Access Event

    DS-K3B601SX Series Swing Barrier User Manual sending an email. Once an event is triggered, the client will notify the security personnel, so that he/she can handle the event in time. Before You Start Add access control device to the client. Steps 1.
  • Page 98 DS-K3B601SX Series Swing Barrier User Manual Steps Note The linkage actions should be supported by the device. 1. Click Access Control → Linkage Configuration . 2. Select the access control device from the list on the left. 3. Click Add to add a new linkage. 4.
  • Page 99: Configure Device Actions For Card Swiping

    DS-K3B601SX Series Swing Barrier User Manual Edit Linkage Select the configured linkage settings in the device list and you can edit Settings its event source parameters, including event source and linkage target. Delete Linkage Select the configured linkage settings in the device list and click Delete Settings to delete it.
  • Page 100: Door Control

    DS-K3B601SX Series Swing Barrier User Manual Note The device should support alarm input function. Access Point The door status of open, close, remain open, or remain closed will be triggered. Audio Play The audio prompt will be triggered. And the select audio index related audio content will be played according to the configured play mode.
  • Page 101 DS-K3B601SX Series Swing Barrier User Manual Steps 1. Click Monitoring to enter the status monitoring page. 2. Select an access point group on the upper-right corner. Note For managing the access point group, refer to Group Management . The doors in the selected access control group will display. 3.
  • Page 102: Check Real-Time Access Records

    DS-K3B601SX Series Swing Barrier User Manual Result The icon of the doors will change in real-time according to the operation if the operation is succeeded. 7.9.2 Check Real-Time Access Records The access records will display in real time, including card swiping records, face recognitions records, fingerprint comparison records, etc.
  • Page 103: View Real-Time Events

    DS-K3B601SX Series Swing Barrier User Manual Steps 1. Click → Tool → Device Arming Control to open Device Arming Control page. All the added devices appear on this page. 2. Optional: If there are to many devices, enter the key words in Filter filed to filter the device(s) you want.
  • Page 104 DS-K3B601SX Series Swing Barrier User Manual Event Time For encoding device, event time is the client time when it receives the event. For other device types, event time is the time when the event is triggered. Priority Priority represents the emergency degree of the event. 2.
  • Page 105: Search Historical Events

    DS-K3B601SX Series Swing Barrier User Manual Download Captured Hover the cursor on the captured picture, and click the download Picture icon on the lower right corner of the picture to download it to the local PC. Download Event Hover the cursor on the recorded video, click to download the Triggered Video video (30s before the event happens) triggered by the event.
  • Page 106 DS-K3B601SX Series Swing Barrier User Manual Note You can enter a key word (supports fuzzy search) in the search box to search the target event type(s). Status The handling status of the event. Search by Keyword Enter a key word (supports fuzzy search) to quickly search the target historical event(s). For example, you can enter a person's name to search the events related with this person.
  • Page 107 DS-K3B601SX Series Swing Barrier User Manual Figure 7-15 Search Historical Event 4. Optional: Right click the table header of the event list to customize the event related items to be displayed in the event list. 5. Select an event in the event list to view the event details. 6.
  • Page 108: Remote Configuration Via Client Software

    DS-K3B601SX Series Swing Barrier User Manual Send Email Select an event and then click Send Email, and the information details of this event will be sent by email. Note You should configure the email parameters first, see Set Email Parameters in the user manual of the client software for details. Export Event Click Export to export the event log or event pictures to the local PC in Information...
  • Page 109: Set System Maintenance

    DS-K3B601SX Series Swing Barrier User Manual 4. Optional: Check Enable NTP and set the NTP server address, the NTP port, and the synchronization interval. 5. Optional: Check Enable DST and set the DST start time, end time and the bias. 6.
  • Page 110: Manage Keyfob User

    DS-K3B601SX Series Swing Barrier User Manual 5. Optional: Select a user in the user list and click Edit to edit the user. You are able to edit the user password, the IP address, the MAC address and the user permission. 6.
  • Page 111: Configure Lane Parameters

    DS-K3B601SX Series Swing Barrier User Manual 7.11.8 Configure Lane Parameters You can set the passing parameters for a person to pass through the turnstile. Steps 1. Click Maintenance and Management → Device to enter the device list. 2. Click to enter the remote configuration page. 3.
  • Page 112: Configure Screen Parameters

    DS-K3B601SX Series Swing Barrier User Manual Note For better performance, it is suggested to use the default parameters. Screen Position Select the screen's position on the device. If select Exit from the drop-down list, the screen will be installed at the exit position of the device. Screen Model Select the screen model from the drop-down list.
  • Page 113: Configure Advanced Network

    DS-K3B601SX Series Swing Barrier User Manual If enabling the function and if the device is offline, the device will continue counting the people and the number will be stored in the device. When the device is online, the client will read the updated number from the device automatically.
  • Page 114: View Relay Status

    DS-K3B601SX Series Swing Barrier User Manual 6. Click Save Parameters to save the relationship between the index (the playing content) and the play scene. 7. Optional: Click Export to export the default audio file to the local computer. 8. Optional: Click ... and select audio file from the local computer. Click Import to import the file to the device.
  • Page 115: Appendix A. Tips For Scanning Fingerprint

    DS-K3B601SX Series Swing Barrier User Manual Appendix A. Tips for Scanning Fingerprint Recommended Finger Forefinger, middle finger or the third finger. Correct Scanning The figure displayed below is the correct way to scan your finger: You should press your finger on the scanner horizontally. The center of your scanned finger should align with the scanner center.
  • Page 116 DS-K3B601SX Series Swing Barrier User Manual Others If your fingerprint is shallow, or it is hard to scan your fingerprint, we recommend you to use other authentication methods. If you have injuries on the scanned finger, the scanner may not recognize. You can change another finger and try again.
  • Page 117: Appendix B. Dip Switch

    DS-K3B601SX Series Swing Barrier User Manual Appendix B. DIP Switch B.1 DIP Switch Description The DIP switch is on the main lane control board. No.1 to No 8 is from the low bit to the high bit. When the switch is towards ON, it means the switch is enabled, otherwise, the switch is off. If you set the DIP switch like the figure displayed below, its binary value is 00001100, and its decimal value is 12.
  • Page 118 DS-K3B601SX Series Swing Barrier User Manual Device Mode Function Decimal Value DIP Switch Address Diagram Disable Memory Mode Keyfob Paring Disable Keyfob Mode Paring Mode Enable Keyfob Paring Mode 5 to 8 Passing Mode Controlled Bi- direction Controlled Entrance and Prohibit Exit Controlled Entrance and Free...
  • Page 119 DS-K3B601SX Series Swing Barrier User Manual Device Mode Function Decimal Value DIP Switch Address Diagram Prohibit Entrance and Controlled Exit Prohibit Entrance and Free Exit...
  • Page 120: Appendix C. Event And Alarm Type

    DS-K3B601SX Series Swing Barrier User Manual Appendix C. Event and Alarm Type Event Alarm Type Tailgating Visual and Audible Reverse Passing Visual and Audible Force Accessing None Climb over Barrier Visual and Audible Overstay Visual and Audible Passing Timeout None Intrusion Visual and Audible Free Passing...
  • Page 121: Appendix D. Table Of Audio Index Related Content

    DS-K3B601SX Series Swing Barrier User Manual Appendix D. Table of Audio Index Related Content Index Content Authenticated. Card No. does not exist. Card No. and fingerprint mismatch. Climbing over the barrier. Reverse passing. Passing timeout. Intrusion. Force accessing. Tailgating. No permissions. Authentication time out.
  • Page 122 DS-K3B601SX Series Swing Barrier User Manual Appendix E. Error Code Description The swing barrier will display the error code on the seven-segment display if error occurred. Refer to the table below to find the description of each number. Error Reason Code Error Reason Code...
  • Page 123 Device Command Scan the following QR code to get the device common serial port commands. Note that the command list contains all commonly used serial ports commands for all Hikvision access control and video intercom devices. Figure F-2 Device Command...
  • Page 124 UD23132B-D...