Removal Of Four Way Valve - Daikin J Series Service Manual

Hide thumbs Also See for J Series:
Table of Contents

Advertisement

SiBE041101
2.6

Removal of Four Way Valve

Procedure
Step
Pull out the electronic
1
expansion valve coil.
Remove the terminal
2
cover.
Disconnect the lead
3
wires of the
compressor.
Removal Procedure
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Red (U)
Yellow (V)
Blue (W)
Outdoor Unit - RK(X)S20/25/35J2V1B
Electronic
expansion
valve coil
(R7233)
Terminal cover
(R7234)
(R7235)
Points