Removal of Four Way Valve

6. Removal of Four Way Valve
Procedure
Step
1
Pull out the electronic
expansion valve coil.
Remove the terminal
2
cover.
Disconnect the lead
3
wires of the
compressor.
18
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Red (U)
Yellow (V)
Blue (W)
Electronic
expansion
valve coil
(R7233)
Terminal cover
(R7234)
(R7235)
Si00-772
Points
The cooling only models do
not have a four way valve
coil.
Removal Procedure