Control Specification
3.5

Input Current Control

Outline
The microcomputer calculates the input current during the compressor is running, and sets the
frequency upper limit from the input current.
In case of heat pump model, this control which is the upper limit control of the frequency takes
priority to the lower limit of control of four way valve operation compensation.
Detail
Frequency control in each zone
Stop zone
Drooping zone
Keep zone
Reset zone
A
B
C
A
B
C
Limitation of current drooping and stop value according to the outdoor temperature
41
(A)
A
B
C
Input current
After 2.5 seconds in this zone, the compressor is stopped.
The upper limit of the compressor frequency is defined as operation frequency – 2 Hz.
After this, the output frequency is pulled down by 2 Hz every second until it reaches the keep
zone.
The present maximum frequency goes on.
Limit of the frequency is canceled.
(A)
(A)
Normal mode
ECONO mode
(A)
Normal mode
ECONO mode
(A)
(A)
Normal mode
ECONO mode
(A)
Normal mode
ECONO mode
The current droops when outdoor temperature becomes higher than a certain level
(depending on the model).
Compressor Stop
20 class
Cooling
Heating
Cooling
9.25
6.0
7.5
6.25
3.25
5.25
6.75
5.5
2.5
42 class
Cooling
Heating
Cooling
14.25
10.0
10.5
10.0
4.5
7.0
9.0
9.5
9.0
3.5
6.0
Stop Zone
Drooping Zone
Keep Zone
Reset Zone
(R14246)
25 class
35 class
Heating
Cooling
9.25
9.25
7.5
8.25
3.25
3.25
6.75
2.5
50 class
Heating
20.0
15.0
10.5
14.0
9.5
Function and Control
SiBE041101
Heating
7.5
2.5

Hide quick links: