Intermec Sabre 1555 Programmer's Reference Manual page 87

Rfid & bar code reader
Hide thumbs Also See for Sabre 1555:
Table of Contents

Advertisement

Table 4-33 RFID Auto Configuration Commands (continued)
Define RFID Auto Read Parameters
Command Name
Defines the auto read parameters in the tags.
Description
Read field [0 - 3], 1 byte, hexadecimal
Start address [0 - 127], see Appendix C, base 64
Parameters
Read size [1 - 32], 2 bytes, see Appendix C, base 64.
Note: Sum of start address and read size must not exceed 128
ACC (command accepted)
Responses
NAC (command not recognized, or parameters invalid)
RFID Operating Mode Selection
Command Name
Defines the current operating mode. AutoRun activates RFID operating mode.
Description
Set bits to activate fields:
0x01 = Tag Identify *default
0x05 = Tag Read
0x09 = Tag Write
Parameters
0x0D = Tag Read Write
0x11 = Tag Filter
0x15 = Tag Filter Read
0x19 = Tag Filter Write
0x1D = Tag Filter Read Write.
ACC (command accepted)
Responses
NAC (command not recognized)
Define RFID Auto Run Response
Command Name
Defines whether the RFID Auto Run Response will contain complete or partial success
status.
Example: For an RFID Read operation of more than one field, when complete success
Description
is activated, the BFR success frame is sent only if all fields selected are read correctly.
With partial success, the BFR partial success frame is sent, but the bit status must be
checked for each field read.
Default is complete success.
[0 - 1]; 0: partial success; 1: complete success
Parameters
ACC (command accepted)
Responses
NAC (command not recognized)
Interactive Programming Mode
<TYPE> <CMD>: \0D\4C\58 + Prms
<TYPE> <CMD>: \0D\4D\40 + Prms
<TYPE> <CMD>: \0D\4D\42 + Prms
4
4-47

Advertisement

Table of Contents
loading

Table of Contents