4. Bar Code Field, cont.
EasyCoder E4 Direct Protocol v2.10 – Programmer's Reference Manual
Set Bar Code Height
The height of the bars that make up the bar code can be specifi ed
using the BARHEIGHT command.
BARHEIGHT | BH <height>
<height>
Default:
Reset to default by:
Set Bar Code Ratio
The ratio between the wide and the narrow bars can be set using
a BARRATIO command.
BARRATIO | BR <wide bars>,<narrow bars>
<wide bars>
<narrow bars>
Default:
Reset to default by:
Set Bar Code Magnifi cation
The magnifi cation of the bar code and the bar code ratio decides
the actual thickness of the bars. For example, if BARRATIO is
3:1 and BARMAG is 2, then the wide bars will be 6 dots thick (3 ×
2) and the narrow bars will be 2 dots (1 × 2). Magnifi cation also
affects interpretations that are integrated in the code, for example
EAN and UPC codes.
BARMAG | BM <magnifi cation>
<magnifi cation>
Default:
Reset to default by:
Chapter 4
the height of the bars in dots
100
PRINTFEED|PF
width of wide bars in dots
width of narrow bars in dots
3:1
PRINTFEED|PF
the enlargement factor of the bar code pat-
tern.
2
PRINTFEED|PF
Label Design