Value
Stop charge if
StartTransaction replies
ConcurrentTx
Require auth. At remote
Start
Active Power in
MeterValues
Heartbeat interval
Connection timeout
Meter value sample
interval
Yes: Stop existing charge transaction after response from
backend (StartTransaction.conf) when user has already
involved in another transaction.
No: Charge transaction does not stops even if backend
rejects the user. (StartTransaction.conf)
NOTE: Set this option according to your backend system.
Yes: Charge point sends an authorization request before
starting a new remote charge transaction request.
No: Charge point starts a new remote charge transaction
without authorization request.
Yes: Send power (Power.Active.Import) and energy
(Energy.Active.Import.Register) consumed by the vehicle
within meter values requests.
No: Only energy consumed is sent within meter values
request.
Heartbeat send interval (in seconds) for the back-end
system.
Timeout (in seconds) before connecting to the central sys-
tem.
Meter value sample send interval (in seconds) during
charge transaction.
NOTE: Meter values are disabled if 0 seconds is set