Master/Slave Instruction Manual
Value
Metervalue sample
interval
Transaction
message retry
interval
Charging cable
connection timeout
Local authList
enabled
Local auth list
max. length
Send local list
max. length
Reserve connector
zero supported
82
Number of seconds between MeterValue during an ongoing
Charge Transaction.
*NOTE: setting this value to 0 disables the MeterValue.
Number of seconds between transaction message attempts.
*NOTE: setting this value to 0 disables the attempts.
Number of seconds the Charge Point must wait for the user to
plug/unplug the cable.
*NOTE: this field is for information purposes, it cannot be
modified.
Yes: Local Authorization List enabled
No: Local Authorization List disabled
Maximum size of the Local Authorization List , a list of identifiers
that can be synchronized with the Central System.
It can be viewed accessing to the following URL:
http://<IP>:8080/services/cmd/dump_localList.xml
*NOTE: this field is for information purposes, it cannot be modified.
Maximum number of identifications that can be send in a single
request from the Central System.
*NOTE: this field is for information purposes, it cannot be modified.
Yes: Charge Point supports reservations on connector 0. That
reservervation is not done on a specific connector, one connector
remains available for the reserved idTag.
No: Charge Point does NOT support reservations on connector 0.