14.5 REGULATION OF THE WATER FEED VALVE
The water feed valve is preset to factory default values. These may change due
to possible shocks and vibrations during transportation.
In this case, the water feed valve has to be reset properly by authorized
servicing personnel.
The water feed valve functions properly when tepid water is discharged from
appliance during the operation of the compressor unit; the water flow stops
when the appliance stops. Water consumption increases if the temperature of
cooling water exceeds 18° C.
14.6 ENVIRONMENT TEMPERATURES BELOW 0° C
Do not leave the appliance in an environment colder than 0ºC (273K). If this is
the case, discharge water from the condenser.
To empty the water out of the appliance, detach the cap of the safety valve at it
is bottom. When all water has been discharged, put the cap back in position.
Open the safety valve and empty the system.
When the system is empty close the valve.
70
CONDENSER
SAFETY VALVE