12.4 TESTING START UP

Testing start up of the appliance:
make sure that the control panel is in STOP state;
make sure that the outlet pipe is properly set and well closed
open the cover lid ;
fill the basin with 30 cm of water (double click DESIRED TEMPERATURE
key);
lower – close cover lid;
press MIXING MODE key and check mixer operation;
press STOP / RESET key;
open outlet pipe and empty the water from the basin.

12.5 REGULATION OF THE WATER FEED VALVE

The water feed valve is preset to factory default values. These may change due to
possible shocks and vibrations during transportation.
In this case, the water feed valve has to be reset properly by authorized servicing
personnel.
The water feed valve functions properly when tepid water is discharged from
appliance during the operation of the compressor unit; the water flow stops when
the appliance stops. Water consumption increases if the temperature of cooling
water exceeds 18° C.
12.6 ENVIRONMENT TEMPERATURES BELOW 0° C
Do not leave the appliance in an environment colder than 0ºC (273K). If this is the
case, discharge water from the condenser.
To empty the water out of the appliance, detach the cap of the safety valve at it's
bottom. When all water has been discharged, put the cap back in position.