Wiring Requirements; Dc Wiring - Xantrex TRUECHARGE 2 Installation Manual

Hide thumbs Also See for TRUECHARGE 2:
Table of Contents

Advertisement

Installation

Wiring Requirements

WARNING: Shock and fire hazard
Wiring and fuse sizes are governed by electrical codes and
standards. Different requirements apply in different countries and to
different types of installations, for example, boat, home or RV. It is
the responsibility of the installer to ensure that each installation
complies with all applicable codes and standards.
WARNING: Shock and fire hazard
Ensure that wires and fuses or breakered disconnects are correctly
sized.
Maximum continuous current available from the charger may be an
additional 6–10% above the nominal current rating of the charger.

DC Wiring

The following two tables show some typical wire sizes for
various cable length runs, based on 3% voltage drop on DC
cables, 75 °C (167 °F) rated wire with wiring being inside the
engine compartment – assumed ambient of 50 °C (122 °F).
Table 2-1 DC Wiring Examples for 12 V chargers
Wire Length
(max length one
way)
feet
meters
5
1.5
7.5
2.25
20
6
a.Values based on American Boating and Yachting Council E-11 2008 Table VI-A and
Table IX.
2–8
This guide for use by qualified installers only
Elcodis.com
electronic components distributor
All manuals and user guides at all-guides.com
Wire Size (AWG and mm
TC1012
TC1512
TC2012
No. 14
No. 12
No. 10
2
2
2 mm
3.3 mm
5.3 mm
No. 12
No. 10
No. 10
2
2
3.3 mm
5.3 mm
5.3 mm
No. 8
No. 6
No. 6
2
2
8.4 mm
13.3 mm
13.3 mm
a
2
)
TC3012
TC4012
TC5012
No. 10
No. 8
No. 6
2
2
2
5.3 mm
8.4 mm
13.3 mm
No. 8
No. 6
No. 6
2
2
2
8.4 mm
13.3 mm
13.3 mm
No. 4
No. 2
No. 2
2
2
2
21.2 mm
33.6 mm
33.6 mm
975-0402-01-01
TC6012
No. 6
2
2
13.3 mm
No. 4
2
2
21.2 mm
No. 1
2
2
42.4 mm

Advertisement

Table of Contents
loading

Table of Contents