I Fuse Replacement - Icom IC-M802 Instruction Manual

Mf/hf marine transceiver
Hide thumbs Also See for IC-M802:
Table of Contents

Advertisement

13
CONFECTION AND INSTALLATION

I Fuse replacement

The transceiver has 2 fuses (2 types) to protect inter-
nal circuitry, 1 fuse for the fuse holder on the DC power
cable and 1 for inside. If the transceiver stops func-
tioning, check the fuses below.
• DC power cable .................................FGB 30 A
• Circuitry fuse .......................................FGB 5 A
D Internal fuse replacement
q Unscrew 8 screws from the top cover, then remove
the cover.
w Unscrew 8 screws from the PA shield cover, then
open the cover.
• The cooling fan is fixed with the PA shield cover.
• Move the coaxial cable as shown in the diagram.
• Be careful the cooling fan power cables are still con-
nected.
Coaxial
cable
D Line fuse replacement
60
CAUTION: DISCONNECT the DC power cable from
the transceiver when changing a fuse.
e Replace the circuitry fuse as shown in the diagram
below.
• Use the supplied FGB 5 A fuse (glass tube type).
r Attach the PA shield cover, coaxial cable and top
cover to their original position.
FGB 30 A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents