Settings; Prerequisites - Otto Bock Start M1 Instructions For Use (Qualified Personnel

Table of Contents

Advertisement

Settings

CAUTION
Failure to verify readiness for use before putting into operation
Tipping, falling due to incorrect adjustment or installation
► Check the existing settings prior to first use.
► After every assembly, check for proper mounting of the rear wheels. The quick-release axles must be securely
locked in the receiver bushings.
► Pay particular attention to the stability against tipping, free running of the rear wheels and correct function of
the wheel locks.
► Check the tyre pressure. The correct tyre pressure is printed on the sidewall. Ensure that the pressure is the
same in both tyres.
A few simple steps are sufficient for preparing the wheelchair for use:
1) Attach the rear wheels to the quick-release axle housings. The quick-release axles must not be able to be
removed after the push-button has been released.
2) Unfold the wheelchair.
3) Attach the footrests.
4) Pull the part of the flap that can be fastened forward and attach it to the seat upholstery with the hook-and-loop
fastener.
5) If necessary: Fit the seat cushion. The seat cushion is secured against sliding by being pressed on to the
hook-and-loop fastener.
6 Settings

6.1 Prerequisites

WARNING
Incorrect settings
Tipping over, falling or malposition of the user due to incorrect settings
► Adjustment and installation work may only be completed by instructed, qualified personnel.
► Only the settings described in these instructions for use may be carried out.
► Settings may only be changed within the allowable adjustment ranges; otherwise, the stability of the product
may be impaired (see this chapter and the chapter "Appendices"). If you have questions, contact the manu­
facturer's service (see back cover for addresses).
► Only conduct tests in the presence of an assistant.
► Unless expressly described, you may not change any settings with a person sitting in the product.
► Secure the user against falling out during all tests.
► Before testing setting changes with the user seated, firmly tighten all screw connections.
► Check for safe function before delivering the product.
CAUTION
Unsecured screw connections
Pinching, crushing, tipping over, falling of user due to assembly errors
► After all adjusting/readjusting work, retighten the mounting screws/nuts firmly. Observe any torque settings
which may be specified.
► Any time you loosen a screw connection with thread lock, replace it with a new screw connection with thread
lock or secure the old screw connection with medium strength thread locker (e.g. Loctite
CAUTION
Improper use of self-locking nuts
Tipping, falling over of the user due to screw connections coming loose
► Always replace self-locking nuts with new self-locking nuts after disassembly.
Adjustments to match the concrete physical and mental condition of the user should always be made in the user's
presence.
All parts of the product should be cleaned thoroughly before adjustments are made.
8 | Ottobock
®
241).
Start M1

Advertisement

Table of Contents
loading