Chapter 3. General Specifications
Chapter 3. General Specifications
3.1 General specifications
The following shows the general specifications of the K series.
No.
Item
Operating ambient
1
Temperature
Storage ambient
2
Temperature
Operating ambient
3
Humidity
Storage ambient
4
Humidity
5
Vibrations
6
Shocks
7
Noise Immunity
8
Atmosphere
9
Altitude
10
Pollution degree
11
Cooling method
REMARK
1)
IEC (International Electrotechnical Commission): An international civilian institute who establishes international standards in area of electric
and electronics.
2) Pollution degree: An indicator, which indicates pollution degree, which determine insulation performance of equipment.
Pollution degree 2 : Normally, only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by
condensation shall be expected.
0 ~ 55 °C
−25 ~ +70°C
5 ~ 95%RH, non-condensing
5 ~ 95%RH, non-condensing
Occasional vibration
Frequency
Acceleration
10≤ f < 57Hz
−
57≤ f ≤ 150Hz
2
9.8m/s
{1G}
Continuous vibration
Frequency
Acceleration
10≤ f < 57Hz
−
57≤ f ≤ 150Hz
2
4.9m/s
{0.5G}
• Maximum shock acceleration: 147 m/s
• Duration time: 11ms
• Pulse wave: half sine pulse( 3 shocks per axis, on X, Y, Z axis )
Square wave
± 1,500 V
Impulse noise
Electronic
Voltage: 4 kV ( Discharge by contact )
discharge
Radiated
electromagnetic
27 ~ 500 MHz, 10 V/m
field noise
Item
Fast transient &
burst noise
Voltage
Free of corrosive gases and excessive dust
Up to 2,000m
2
Air-cooling
3 -
Specifications
Amplitude
0.075mm
−
Amplitude
0.035mm
−
2
{15G}
Digital I/O
Power supply
(>24V)
2kV
1kV
References
-
Sweep count
IEC 61131-2
10 times for each X,
Y, Z axis
IEC 61131-2
LGIS' Internal
Standard
IEC 61131-2,
IEC 801-2
IEC 61131-2,
IEC 801-3
Digital I/O
(<24V)
IEC 61131-2
Analog I/O
IEC 801-4
Interface
0.25kV
IEC61131-2
Need help?