Chapter 7 Usage of Functions
7.2.2 Analog timer
1) Performance specification
The performance specification of the analog timer module are following.
Item
Number of channels
Output value range
Setting type
Accuracy of timer
Operation method
Internal current
consumption
Number of module
installment
Weight
2) Names of parts and functions
No.
Name
RUN LED
Channel
Extension cable
Extension cable connection terminal
4
8 Bit (Digital output range: 0
Setting by variable resistance
2.0% (Accuracy about max. value)
Storing data register automatically
50
Max 3 modules
200g
②
③
Contents
Indicate the operating status the G7F-AT2A.
On: normal operating
Off:
DC 5V power off or the g7f-at2a module fault
Setting up the length of timer through variable resistance to every
channel.
7- 59