[B] Unit With Water Tank, Water Softener & Water Filter - Hoshizaki ROX-20TA-U Instruction Manual

Water electrolyzer
Hide thumbs Also See for ROX-20TA-U:
Table of Contents

Advertisement

[b] UNIT WITH WATER TANK, WATER SOFTENER & WATER FILTER
1. Do not run the water electrolyzer until adequate water pressure (15-115PSIG
(0.10-0.78MPa)) is reached.
2. The vertical height of the pipe and total length of the pipes for acid and alkaline
water should be the same. Different pipe lengths may cause an unstable amount
of acid and alkaline water to be generated, poor performance or damage to
the unit.
3. Keep the end of the electrolytic water pipes open. Do not install a shut-off valve
on the end of the pipe, connect a hose with the end of the water outlet or immerse
the end of the pipe in water. Different pipe lengths may cause an unstable
amount of acid and alkaline water to be generated, poor performance or
damage to the unit.
4. Pour electrolytic water down a drain after it is neutralized. Putting electrolytic
water down a drain without neutralizing it may cause rusty pipes and water
leakage.
5. Do not install the unit where there is a possibility of freezing. Remove water
from the unit if ambient temperature may fall below 32°F (0°C). Frozen water
may damage water supply pipes and cause water leakage.
6. Maintain water supply pressure to the unit within 15-115PSIG (0.10-0.78MPa).
Excessively low or high water pressure may cause poor performance of acid
and alkaline water, trouble or water leakage from the connections.
7. Use the Accessory Braided Hoses, Connectors and Gaskets or PVC pipes for
electrolytic water piping. Other materials may cause corrosion and water
leakage.
8. Use sealing agents, sealing tape or gaskets to prevent water leakage when
connecting pipes.
* Be sure to install the Pressure Reducing Valve
after the Water Filter and Water Pressure Gauge.
Pressure Reducing Valve Inlet is 1/2" male pipe
thread (MPT). The water electrolyzer will not work
properly without the Pressure Reducing Valve.
Note: Be sure to check the direction of the
Pressure Reducing Valve. See Fig. 22.
CAUTION
Outlet
25
Inlet
Fig. 22