2. The water softener requires a ground that meets the national and local electrical
code requirements. To prevent possible electrical shock to individuals or
extensive damage to equipment, plug the water softener only into a properly
grounded electrical outlet.
The maximum allowable voltage variation should not exceed ±10 percent of the
rated voltage. Operation of the unit outside of this range may cause damage to
the unit or reduction of the performance.
* Usually an electrical permit and services of a licensed electrician are required.
[e] WATER SUPPLY AND PLUMBING CONNECTIONS – See Fig. 3
Do not run the Water Softener and the Water Filter until the proper water pressure
is reached.
* For piping of the Water Softener and Water Filter, follow the Instruction Manual for the Water
Softener and the Water Filter.
* Adjust water pressure so that discharge pressure after pipes are connected will be within
15-115PSIG (0.10-0.78MPa). Also adjust water supply pressure so that it will be within the
specified value in the specifications for the Water Softener and the Water Filter (softener is
NSF rated at 120PSI and flow of 2gal./min.).
* Install a water pressure gauge on the pipe of the primary side of the Water Softener and
secondary side of the Water Filter.
* For air gap between the drain pipe ends or hose ends and a sink or floor drain, follow the
Instruction Manual for the Water Softener.
* Be sure to flush out a new water softener thoroughly to a sink or drain before connecting it to
the water electrolyzer.
* A plumbing permit and services of a licensed plumber may be required in some areas.