[d] ELECTRICAL CONNECTION

* Usually an electrical permit and services of a licensed electrician are required.
1) Remove the Rear Panel. See "III. 2. HOW TO REMOVE PANELS".
2) Connect the cable connector on the Remote Controller with the 8P connector on the back
of the Control Box. See Fig. 8.
3) Remove one blind bushing from the unit base and attach the cable to the unit base using
the bushing on the Remote Controller. See Fig. 9.
4) Replace the Rear Panel in the original position with screws.
8P Connector
Remote
Controller
Cable
7. INSTALLATION OF WATER TANK FLOAT SWITCHES (OPTION)
AND WATER TANK (SOLD SEPARATELY)

[a] CHECKS BEFORE INSTALLATION

1) Unpack and remove shipping carton, tape(s) and other packaging material(s).
2) Check that all the necessary accessories are included.
3) Check that the water electrolyzer and Water Tank are installed so that the cables of the
Float Switches can reach from the water electrolyzer to the Water Tank.
4) A stand may be needed to support the Water Tank depending on the application. Check if
the floor can support the weight of the Water Tank when it is full.
5) The Water Tank should have a cover with a small ventilation opening to the atmosphere.