of the remote controller for extended periods outside of these normal
temperature ranges may affect performance.
2. Do not install the remote controller where exposed to humidity or splashing
water. Reduction in insulation property may cause an electric leak or shock.
3. Install an adequate ventilating system. Hydrogen gas or chlorine gas may cause
health problems.
1. Avoid a site where dripping is not allowed. Condensation may form on the
exterior in high humidity and could drip onto the floor.
2. Use glass, plastic or stainless steel containers for electrolytic water. Acid water
may corrode metal.
For best operating results:
* The Remote Controller should not be located next to ovens, grills or other high heat producing
equipment.
* Location should provide a firm and level foundation for the equipment.
* Install the unit in a well-ventilated area. Use fans with diameter over 6 inches (standard air
3
flow rate: 270ft
/min (450m

[c] SET UP

Use the Accessory Braided Hoses, Connectors and Gaskets for electrolytic water
piping. Other materials may cause corrosion and water leakage.
1) Secure the Remote Controller to the Bracket with M4 x 8 Tapping Screws (Accessory) as
shown in the illustration. See Fig. 4.
2) Attach the PVC Braided Hose to the Connector with the Clamp. See Fig. 5.
3) Attach the Connectors to the water electrolyzer with the Gaskets between the Connectors
and the water electrolyzer. Make sure to check the connection locations for the Acid and
Alkaline Water Hoses. See Fig. 6.
4) Drive M6 anchor bolts into the wall or attach a sheet metal part to the wall to attach the
CAUTION
3
/h)) if necessary.
CAUTION