[b] LOCATION

1. These float switches and water tank are not intended for outdoor use. Normal
operating ambient temperature should be within +40°F to 95°F (+5°C to +35°C);
Normal operating water temperature should be within +40°F to 85°F (+5°C to
+30°C). Operation of the float switches and water tank for extended periods
outside of these normal temperature ranges may affect performance.
2. Do not install the float switches and water tank where exposed to humidity or
splashing water. Reduction in insulation property may cause an electric leak or
shock.
3. Install an adequate ventilating system. Hydrogen gas or chlorine gas may cause
health problems.
1. Avoid a site where dripping is not allowed. Condensation may form on the
exterior in high humidity and could drip onto the floor.
2. Use glass, plastic or stainless steel containers for electrolytic water. Acid water
may corrode metal.
For best operating results:
* The Water Tank should not be located next to ovens, grills or other high heat producing
equipment.
* Location should provide a firm and level foundation for the equipment.
* Allow min. 24" clearance at rear, sides and top for ease of maintenance and/or service.
* Install the unit in a well-ventilated area. Use fans with diameter over 6 inches (standard air
3
flow rate: 270ft
/min (450m

[c] SET UP

Use the PVC Braided Hoses, Connectors and Gaskets or PVC pipes for
electrolytic water piping. Other materials may cause corrosion and water leakage.
WARNING
CAUTION
3
/h)) if necessary.