Advertisement

3) Install the Outlet Valves on the wall using the M4 x 8 Screws (Accessory), etc. depending
on the installation condition. Install the Outlet Valves on pipes from each Water Tank.
Outlet Valve Inlet is 1/2 Female Pipe Thread (FPT).
Note: When mounting the Valves on a wall surface, locate:
Acid water valve (yellow pipe) on your right
Alkaline water valve (blue pipe) on your left
4) Attach the labels (acid water, alkaline water, and caution) in readily visible positions near
the valves.

9. WATER SUPPLY AND PLUMBING CONNECTIONS

[a] UNIT WITH REMOTE CONTROLLER, WATER SOFTENER & WATER FILTER
1. Do not run the water electrolyzer until adequate water pressure (15-115PSIG
(0.10-0.78MPa)) is reached.
2. The vertical height of the pipe and total length of the pipes for acid and alkaline
water should be the same. Different pipe lengths may cause an unstable amount
of acid and alkaline water to be generated, poor performance or damage to
the unit.
3. Keep the end of the electrolytic water pipes open. Do not install a shut-off valve
on the end of the pipe, connect a hose with the end of the water outlet or immerse
the end of the pipe in water. Different pipe lengths may cause an unstable
amount of acid and alkaline water to be generated, poor performance or
damage to the unit.
4. Pour electrolytic water down a drain after it is neutralized. Putting electrolytic
water down a drain without neutralizing it may cause rusty pipes and water
leakage.
Fig. 15
CAUTION
22