Full Drop And Insert Option Module Specifications - ADTRAN 1200065L1-1 User Manual

Drop and insert option module
Table of Contents

Advertisement

Full Drop and Insert Option Module Specifications

61200065L1-1
Line build-out settings: -22.5, -15, -7.5, 0, and automatic
Monitor jacks
Line loopback (front panel/remote/in-band)
The D & I option module conforms to the following
specifications:
Line rate
Capacity
Line codes
Framing options ESF per ANSI T1.403 and AT&T Publica-
Clock source
Tests
Connectors
Drop and Insert Option Module User Manual
1.544 Mbps
1 to 24 DS0s (can be user configured, con-
tiguous or non-contiguous)
Alternate mark inversion (AMI) Bipolar
Return to Zero (B8ZS)
tion TR 54016 D4 per AT&T Publication
62411
allows secondary T1 to be master timing
source
power-on circuit self test
line loopback
port loopback (internal toward Mux)
RJ48C
Chapter 1. Introduction