Page 3
Affidavit Requirements for Connection to Digital Services • An affidavit is required to be given to the telephone company whenever digital terminal equipment without encoded analog content and billing protection is used to transmit digital signals containing encoded analog content which are intended for eventual conversion into voiceband analog signals and transmitted on the network.
Page 4
Affidavit for Connection of Customer Premises Equipment to 1.544 Mbps and/or Subrate Digital Services For the work to be performed in the certified territory of ________________________(telco name) State of ________________ County of ________________ I, _____________________________ (name), __________________________________(business address), ____________________ (telephone number) being duly sworn, state: I have responsibility for the operation and maintenance of the terminal equipment to be connected to 1.544 Mbps and/or ________ subrate digital services.
Page 5
If they do, you will be given advance notice to give you an opportunity to maintain uninterrupted service. If you experience trouble with this equipment (Octal BRI/U Module), please contact ADTRAN at (256) 963-8000 for repair/warranty information. The telephone company may ask you to discon- nect this equipment from the network until the problem has been corrected or until you are sure the equipment is not malfunctioning.
Page 6
Warranty and Customer Service ADTRAN will replace or repair this product within five years from the date of shipment if the product does not meet its published specification, or if it fails while in service. For detailed warranty, repair, and return information, refer to the ADTRAN Equipment Warranty and Repair and Return Policy Proce- dure (see the last page of this manual).
Page 7
Customer or a third party (including, but not limited to, loss of data or information, loss of profits, or loss of use). ADTRAN is not liable for dam- ages for any cause whatsoever (whether based in contract, tort, or otherwise) in excess of the amount paid for the item.
Introduction Chapter 1 QUAD BRI/U MODULE OVERVIEW The Quad BRI/U Module is a member of the ATLAS 550 family of integrat- ed access products, providing four Basic Rate ISDN (BRI) U interfaces, each capable of operating in either NT or LT mode. Any port can deliver timing for the system.
Chapter 1. Introduction Features The following list describes the features of the Quad BRI/U Module: • Four BRI U Interfaces • Near-end and far-end block error monitoring • Can use any port as a timing source for the entire system •...
Chapter 1. Introduction PHYSICAL DESCRIPTION The Quad BRI/U Module (see Figure 1-2) plugs into any available option slot in the rear of the ATLAS chassis. The four Option slots (labeled 1 — 4) only accept Option Modules, and the Network Interface slots (labeled Network 1 and Network 2) only accept Network Interface Modules.
Carefully unpack and inspect the Quad BRI/U Module for shipping damag- es. If you suspect damage occurred during shipping, file a claim immediate- ly with the carrier and then contact ADTRAN Technical Support (see the last page of this manual for pertinent information). If possible, keep the original shipping container for returning the Quad BRI/U Module for repair or for verification of shipping damage.
Chapter 2. Installation Instructions for Installing the Quad BRI/U Module Step Action Remove the cover plate from the appropriate option slot in the ATLAS rear panel. Slide the Quad BRI/U Module into the option slot until the module is firmly positioned against the front of the chassis. Secure the thumbscrews at both edges of the module.
Chapter 2. Installation WIRING Each module port uses a single RJ-45 jack to connect to a U interface circuit. Table 2-1 shows the network pinout connection. The required wiring con- nection follows: Connector Type (USOC) RJ-45 Table 2-1. Network Pinout Connection NAME DESCRIPTION 1, 2, 3, 6, 7, 8...
Operation Chapter 3 OVERVIEW You can control and configure the Quad BRI/U Module from a variety of sources, including the following: • The terminal menus (both VT-100 and Telnet sessions), allowing de- tailed configuration, status, and diagnostics The remainder of this section describes the menu items presented when managing the Quad BRI/U Module via the terminal menu.
Chapter 3. Operation ODULES The ATLAS system controller automatically detects the presence of the Quad BRI/U Module when it is installed in the system. To see the menus for the Quad BRI/U Module via the terminal menu, use the arrow keys to scroll to the M menu and press to access the module choices.
Chapter 3. Operation Write security: 3; Read security: 5 Displays the type of module actually installed in the slot or the type of module you plan to install in the slot. If a Quad BRI/U Module is installed, the Type field automatically defaults to U-BRI (the Quad BRI/U Module). You can use this field to preconfigure a system before actually installing modules by simply specifying the module that you want to install in each slot.
Chapter 3. Operation The module is enabled, but is not responding to the system controller’s sta- ESPONSE tus polls. This response indicates either a problem in the system or that the module is not installed. The system controller has not detected the presence of a module in the slot, MPTY nor has a module been manually enabled for this option slot.
Chapter 3. Operation LARM Displays port number and alarms. Indicates the port number. Lists the alarms. LARMS HANNEL TATUS Displays the status of each of the Quad BRI/U Module ports. Displays the port number. (Channel) Displays the status of individual channels. The following symbols may display: Unallocated channel Inactive channel...
Chapter 3. Operation ATLAS FEATURES USED WITH QUAD BRI/U MODULE OPTIONS Two additional ATLAS menu items can operate in conjunction with the Quad BRI/U Module: F and R ACTORY ESTORE ELFTEST ACTORY You can restore the factory default settings for an Quad BRI/U Module by pressing F either while the cursor is over the S number (this action re- ESTORE...
Dial Plan Configuration Appendix A DIAL PLAN OVERVIEW The D menu (see Figure A-1) sets configuration parameters for each switched endpoint. These parameters vary by the type of port selected. The following sections describe the configuration options available for the Quad BRI/U Module.
Page 30
Appendix A. Dial Plan Configuration Quad BRI/U Module: Network Termination The Quad BRI/U Module can interface directly with the network (PSTN) and should be configured in the N section of the D ETWORK cordingly. When you are working in the N section of the D ETWORK menu, and S...
Page 31
Appendix A. Dial Plan Configuration TRIP Write security: 3; Read security: 5 Strips a selected quantity (choose from N , 1, 2, and 3) of the Most Signif- icant Digits (MSD) of a dialed number prior to being forwarded out of the port.
Page 32
Appendix A. Dial Plan Configuration WITCH Write security: 3; Read security: 5 Defines the ISDN switch protocol to be emulated on the selected port. If connected to another ATLAS, both need to be set to the same type. Choices include L 5E, N DMS 100, and N -ISDN.
Page 33
Appendix A. Dial Plan Configuration OURCE Write security: 3; Read security: 5 Simplifies the creation of a D in applications where the criterion for switching calls to a certain endpoint is a function of which endpoint origi- nated the call. •...
Page 34
Appendix A. Dial Plan Configuration Quad BRI/U Module User Manual 61200315L1-1...
Page 35
Index network termination on the Quad BRI/U A-2 ATLAS features used with Quad BRI/U 3-6 ATLAS menus and submenus operating the Quad BRI/U module 3-1 Alarm 3-3 operation alarms 2-3 Factory Restore 3-6 Menu 3-3 Modules 3-2 physical description of the Quad BRI/U 1-3 Rev 3-4 pinouts 2-3 Run Selftest 3-6...
Index Index-2 Quad BRI/U Module User Manual 61200315L1-1...
Page 37
(888) 4ADTRAN Repair and Return If ADTRAN Technical Support determines that a repair is needed, Technical Support will coordinate with the Custom and Product Service (CAPS) department to issue an RMA number. For information regarding equipment currently in house or possible fees associ-...
Need help?
Do you have a question about the 1200315L1 and is the answer not in the manual?
Questions and answers