3. 'FLO' Appears on Display (cont.)
PRO TIP: It is always helpful to keep an extra flow switch available for testing
purposes. All Hayward sanitization systems utilize the same flow switch
(GLX-FLO-RP).
Check the Filter
Plug-in a Test Flow Switch
Step 3C
Step 3D
Check the filter & pump basket for excess debris. A
On the panel, locate the interlock connector & replace
clogged filter/pump basket may reduce the flow passing
it with a new flow switch. Leaving the inline switch
through the Hydrorite vessel. IF cleaning is required,
installed, turn the pump on. Manually close the new
clean the filter & recheck. IF the filter/pump basket are
flow switch. IF the error persists, go to 3E. IF the error
both clean, continue to step 3D.
clears go to 3F.