Hayward HydroRite UVO3 Troubleshooting Manual page 49

Hide thumbs Also See for HydroRite UVO3:
Table of Contents

Advertisement

5. Circulation System is Loud
IF either the Vessel or Booster Pump are not secured to the equipment pad, vibration
Vessel is Secured to Pad
Step 5A
Verify that the HydroRite vessel is secured to the
equipment pad. IF the vessel is not secured, securing it
should reduce any noise caused by vibration. IF
secured, continue to step 5B.
49
may cause normal operation to be loud.
Booster Pump is Secured to Pad
Step 5B
Verify the booster pump is secured to the equipment
pad. IF the booster pump is not secured, securing it
should reduce any noise caused by vibration. IF
secured, go to step 5C.