Hayward HydroRite UVO3 Troubleshooting Manual page 39

Hide thumbs Also See for HydroRite UVO3:
Table of Contents

Advertisement

3. 'FLO' Appears on Display
The 'FLO' error message appears when either: flow is not detected by the flow switch
OR the interlock sensor is reporting that the vessel cover is open, make sure the pump
is on and the cover is secure before proceeding.
Verify Main Pump is On
Check the Flow Rate
Step 3A
Step 3B
15GPM
(MIN)
Verify the main pump is running & the vessel is not
Verify that the flow rate is at least 15 gallons per
bypassed. IF OFF, turn the pump on and wait 3 minutes
minute*. IF lower than 15GPM, increase the flow rate
before checking again. After 3 minutes, IF the error still
& retest after 3 minutes. IF the flow rate is greater than
appears, proceed to step 3B.
15GPM, go to step 3C.
*NOTE: 15GPM is enough to satisfy the flow switch requirement, but not enough for
Ozone infusion, which requires 38GPM minimum.
39