4. Vessel is Leaking (cont.)
When quartz sleeves are cracked, water generally works its way up (flooding the
quartz sleeves first). When a quartz sleeve is only partially flooded, this may indicate
that water entered from the top down.
Remove Cables, Sensors, & Lamps
Inspect Vessel's Top Compartment
Step 4C
Step 4D
Remove the vessel cover, remove & disconnect the
With the pump running, inspect the top compartment
lamps, disconnect & remove the sensor cable. With the
to determine the leak path. IF leak path is evident,
cover removed, run the circulation pump. Then procced
replace damaged components or secure loose fittings.
to step 4D.
Otherwise, contact tech support: (908) 355-7995.
*WARNING: Water that has entered the top compartment of the vessel can cause
electrical shorting of components or raise a shock risk, take proper precautions before
troubleshooting a flooded vessel cover.
45