2. Display Not Lit (cont.)
There are two voltage selector plugs: the one located on the main (green) board,
should be set to 230V and the one on the interconnect (blue) board, should be set to
115V. If either of these are incorrect, fuses on the corresponding board may blow.
Test Interconnect Fuses
Verify Voltage Selectors (intercon.)
Step 2G
Step 2H
Test the two interconnect fuses for continuity. These
On the interconnect board, verify the voltage selector is
fuses protect the interconnect board's power circuit. IF
set to 115V*. Once confirmed, replace both fuses
fuse(s) is/are blown, proceed to step 2H. IF fuses are
(HYX2CFK25) & retest. IF fuse immediately fails again,
not blown, jump to step 2I.
replace the board (HYX2CSIPCB).
*NOTE: IF the voltage selector is covered by the following
label, DO NOT remove the label & consider the voltage
selector confirmed.