5. Circulation System is Loud (cont.)
The Needle Valve regulates the amount of vacuum caused by the Venturi. If the
restriction is too great, this can cause the booster pump to sound labored. When a
bypass is engaged, the booster pump should not receive power.
Venturi Needle Valve
Inspect Bypass Valves
Step 5C
Step 5D
Open
Valve
With the booster pump running, close off the needle
Verify the vessel is not being bypassed. IF the vessel is
valve & slowly open it until the booster pump no longer
being bypassed AND the booster pump is still running,
sounds labored. This action will also improve Ozone
shut the system down & immediately contact tech
siphoning. IF correct, proceed to step 5D.
support: (908) 355-7995. IF correct, go to 5E.